Standards and EC Directives
• Conforms to the following EC Directives:
Machinery Directive
Low Voltage Directive
EN60204-1
EN1088
EN50047
EN81
EN115
GS-ET-15
JIS C 8201-5-1

Ordering Information

Model Number Legend
D4F- @@- @@
1
2
3
4
1. Built-in Switch
1:
1NC/1NO (slow-action)
2:
2NC (slow-action)
3:
2NC/2NO (slow-action)
4:
4NC (slow-action)
List of Models
Actuator
Cable
length
Roller lever (Me-
1 m
tallic lever, resin
roller)
3 m
5 m
Roller plunger
1 m
(Metallic roller)
3 m
5 m
Prefered items

Specifications

Approved Standard Ratings
TÜV (EN60947-5-1)
Item
Utilization category
Rated operating current (Ie)
Rated operating voltage (Ue)
Note:
Use a 10-A fuse type gI or gG that conforms to IEC269 as a
short-circuit protection device.
G-260
2. Actuator
02:
Roller plunger
(Metallic roller)
20:
Roller lever
(Metallic lever, resin roller)
Cable
direction
1NC/1NO
(slow-action)
Horizontal
D4F-120-1R
Vertical
D4F-120-1D
Horizontal
D4F-120-3R
Vertical
D4F-120-3D
Horizontal
D4F-120-5R
Vertical
D4F-120-5D
Horizontal
D4F-102-1R
Vertical
D4F-102-1D
Horizontal
D4F-102-3R
Vertical
D4F-102-3D
Horizontal
D4F-102-5R
Vertical
D4F-102-5D
AC-15
DC-13
0.75 A
0.27 A
240 V
250 V
Approved Standards
Agency
TÜV Product
EN60947-5-1
service
(Direct opening: approved)
UL (See note 2.)
UL508
CSA C22.2 No.14
Note:
1. Contact your Omron sales representative.
2. Approval has been obtained for CSA C22.2 No. 14
under UL.
3. Cable Length
4. Pull-outing direction of cable
1:
1 m
3:
3 m
5:
5 m
Built-in switch
2NC
2NC/2NO
(slow-action)
(slow-action)
D4F-220-1R
D4F-320-1R
D4F-220-1D
D4F-320-1D
D4F-220-3R
D4F-320-3R
D4F-220-3D
D4F-320-3D
D4F-220-5R
D4F-320-5R
D4F-220-5D
D4F-320-5D
D4F-202-1R
D4F-302-1R
D4F-202-1D
D4F-302-1D
D4F-202-3R
D4F-302-3R
D4F-202-3D
D4F-302-3D
D4F-202-5R
D4F-302-5R
D4F-202-5D
D4F-302-5D
UL/CSA (UL508, CSA C22.2 No. 14)
C300
Rated
Carry
voltage
current
Make
120 VAC
2.5 A
15 A
240 VAC
7.5 A
Q300
Rated
Carry
voltage
current
Make
125 VDC 2.5 A
0.55 A
250 VDC
0.27 A
Safety Sensors / Components
Standards
File No.
(See note 1.)
E76675
R:
Horizontal
D:
Vertical
4NC
(slow-action)
D4F-420-1R
D4F-420-1D
D4F-420-3R
D4F-420-3D
D4F-420-5R
D4F-420-5D
D4F-402-1R
D4F-402-1D
D4F-402-3R
D4F-402-3D
D4F-402-5R
D4F-402-5D
Current
Volt-amperes
Break
Make
1.5 A
1,800 VA 180 VA
0.75 A
Current
Volt-amperes
Break
Make
0.55 A
69 VA
69 VA
0.27 A
Break
Break

Advertisement