Omron CX-PROGRAMMER 5.0-FUNCTION BLOCK OPERATION Operation Manual page 76

Function blocks
Table of Contents

Advertisement

Instruction Support and Operand Restrictions
Instruction
Mnemonic
DOUBLE
CMPL
UNSIGNED COM-
PARE
SIGNED BINARY
CPS
COMPARE
!CPS
DOUBLE SIGNED
CPSL
BINARY COMPARE
TABLE
TCMP
COMPARE
@TCMP
MULTIPLE
MCMP
COMPARE
@MCMP
UNSIGNED
BCMP
BLOCK
@BCMP
COMPARE
EXPANDED
BCMP2
BLOCK COMPARE
@BCMP2
AREA RANGE
ZCP
COMPARE
Function
Symbol
code
060
114
115
085
019
068
502
088
Operands
S1: Comparison
CMPL
data 1
S1
S2: Comparison
data 2
S2
S1: Comparison
CPS
data 1
S1
S2: Comparison
data 2
S2
S1: Comparison
CPSL
data 1
S1
S2: Comparison
data 2
S2
S: Source data
TCMP
T: 1st word of table WORD
S
R: Result word
T
R
S1: 1st word of set
MCMP
1
S1
S2: 1st word of set
2
S2
R: Result word
R
S: Source data
BCMP
T: 1st word of table WORD
S
R: Result word
T
R
S: Source data
BCMP2
T: 1st word of block WORD
S
T
R: Result word
R
CD: Compare data
ZCP
(1 word)
CD
LL: Lower limit of
range
LL
UL: Upper limit of
UL
range
Section 2-6
Supported
AT
variable
setting or
data types
array
variable
required
(Required
word data
size
shown in
parenthe-
ses.)
UDINT
---
UDINT
---
INT
---
INT
---
DINT
---
DINT
---
WORD
---
Yes (16)
UINT
---
WORD
Yes (16)
WORD
Yes (16)
UINT
WORD
---
Yes (32)
UINT
---
WORD
---
Yes (not
fixed)
WORD
---
UINT
---
UINT
---
UINT
---
61