Editing Unit Parameters
5-1-1

Editing Memory Area Parameters

Edit Memory Area
Parameter Window
Editing Memory Area Parameters
1,2,3...
Note
Select Memory Area Setting from the tree.
1. Set the Output Memory Area (PLC to Position Control Unit).
Click the drop-down list of the Output Memory Area (PLC to Position Con-
trol Unit) and select an appropriate area type from the list.
In the right box, set the beginning address of the specified area type. The
setting range varies depending on the selected area type and the largest
axis No. of the registered axes. When a value out of the range is entered,
the value will be displayed in red. Enter a value within the range.
2. Set the Input Memory Area (Position Control Unit to PLC)
Click the drop-down list of the Input Memory Area (Position Control Unit to
PLC) and select an appropriate area type from the list.
In the right box, set the beginning address of the specified area type. The
setting range varies depending on the selected area type and the largest
axis No. of the registered axes. When a value out of the range is entered,
the value will be displayed in red. Enter a value within the range.
When selecting the same area type for the Output and Input Memory Areas,
make sure to set the appropriate beginning addresses so that the areas do
not overlap. Do not set EM banks that do not exist in the PLC being used as
the areas used for the Output and Input Memory Areas.
Section 5-1
35