Operating Procedure Example - Omron CJ - 12-2004 Manual

Id sensor units
Table of Contents

Advertisement

Operating Procedure
2-2-2

Operating Procedure Example

ID Sensor Unit Settings
1,2,3...
The following is an operating procedure example for the following conditions.
Reading 10 Bytes of Data from Data Carrier Address 0010 Using a Trigger
CS-series CPU Unit
Special I/O
Unit Area
Bit
Bit
15
00
D1000
01
02
D1001
03
04
D1002
05
06
D1003
07
08
D1004
09
0A
→: Read data storage order
Special I/O Unit Area Settings
Unit No.: 00
Command: Read
Communications specification: Trigger
Read data storage order: Leftmost → Rightmost
First Data Carrier read address: 0010 (hex)
Number of Data Carrier read bytes: 10 bytes
Read data storage destination: D1000 to D1004
1. Communications Test Switch (Set on Unit's front panel.)
2. Mounting and Installation
CS1W-V600C11
V600C11
RUN
ERP
ERC
ERH
T/R
Read command
NORM/ERR
TEST
ON
HEAD
Read data
TEST
ON
Section 2-2
Data Carrier
Bit
Address
7
(hex)
0010
0
1
0011
0
2
0012
0
3
0013
0
4
0014
0
5
0015
0
6
Communi-
0016
0
7
cations
0017
0
8
0018
0
9
0019
0
A
Communications test switch