5-3 I/O Allocation DM

Word(s)
2022
Specifies the Inverter operation in case a fatal error occurs in the program.
(Leftmost 3 digits are invalid.).
When last digit is other than 1: Data to Inverter is cleared continuously.
When last digit is 1: Data to Inverter is frozen.
2023
Destination address for storing transferred data (4 digits BCD): L (Note 1.)
2024
Destination address for storing transfer response data (4 digits BCD): K (Note 1.)
2025
Speed feedback
2026
Torque reference (Unit: 0.1%)
2027
Reserved
2028
Frequency reference monitor (Unit: According to n035)
2029
Output frequency monitor (Unit: According to n035)
2030
Output current monitor (Unit: 0.01 A)
2031
Pulse input (Unit: 0.1%)
2032
Main circuit DC voltage monitor (Unit: 1 V)
2033
Reserved
2034
Analog frequency reference terminal monitor (Unit: 0.1%)
2035
Reserved
2036
Frequency reference (Unit: According to n035)
2037 to
Reserved
2040
Note 1
Caution
60
The contents of the DM area is refreshed and updated with each scan.
Function
The value (DM0000 to DM1985) is sampled when the Transfer Command Bit
is turned ON.
At power up, the following words change before they reflect the actual status
of the Inverter:
• DM2032 Main DC voltage monitor
• DM2034 Analog frequency reference terminal monitor
Wait at least 28 ms before using these words.
SECTION 5
Inverter
Read/
Register
write
---
Read/
write
---
Read/
write
---
Read/
write
---
Read-
only
0032
Read-
only
---
Read-
only
0023
Read-
only
0024
Read-
only
0027
Read-
only
---
Read-
only
0031
Read-
only
---
Read-
only
---
Read-
only
---
Read-
only
0002
Read/
write
---
Read/
write