If A Problem Occurs - Sennheiser SK 2000 Instruction Manual

Bodypack transmitter
Hide thumbs Also See for SK 2000:
Table of Contents

Advertisement

... for multi-channel operation
• For multi-channel operation, you should only use the channels within
one frequency bank. Each of the frequency banks "1" to "20" accom-
modates factory-preset frequencies which are intermodulation-free.
• When using several transmitters simultaneously, interference can be
avoided by maintaining a minimum distance of 20 cm between two
transmitters.

If a problem occurs ...

Problem
Bodypack transmitter
cannot be operated,
"Locked" appears on
the display panel
No operation
indication
No RF signal at the
receiver
Possible cause
Lock mode is
activated
Batteries are flat or
accupack is flat
Bodypack trans-
mitter and receiver
are not on the
same channel
Transmission range
is exceeded
RF signal is deacti-
vated
("RF
Mute")
If a problem occurs ...
Possible solution
Deactivate the lock mode
(see page 12).
Replace the batteries or
recharge the accupack
(see page 8).
Set the bodypack trans-
mitter to the same channel
as the receiver.
Synchronize the bodypack
transmitter with the
receiver (see page 28).
Reduce the distance
between bodypack
transmitter and receiving
antennas.
Increase the transmission
power (see page 25).
Activate the RF signal
(see page 13).
31