If a problem occurs ...
SK 100/SKM 100/SKP 100 G3
Problem
Transmitter cannot be
operated, "Locked"
appears on the display
panel
No operation indication
No RF signal at the
receiver
RF signal available,
no audio signal,
"MUTE" appears on the
display panel
Audio signal has a high
level of background noise
or is distorted
If a problem occurs that is not listed in the above table or if the problem cannot be solved with the proposed solutions,
please contact your local Sennheiser partner for assistance. To find a Sennheiser partner in your country, search at
www.sennheiser.com under "Service & Support".
30
Possible cause
Lock mode is activated
Batteries are flat or accupack is flat
Transmitter and receiver are not on the
same channel
Transmission range is exceeded
RF signal is deactivated
("RF
Transmitter is muted (MUTE)
Receiver's squelch threshold is adjusted
too high
Transmitter doesn't transmit a pilot tone Activate or deactivate the pilot tone transmis-
Transmitter's sensitivity is adjusted too
low/too high
Possible solution
Deactivate the lock mode (see page 20).
Replace the batteries or recharge the accupack
(see page 13).
Synchronize the transmitter with the receiver
(see page 19).
Set the transmitter to the same channel as the
receiver.
Reduce the distance between receiver and
transmitter.
Mute")
Activate the RF signal (see page 21).
Cancel the muting (see page 21).
Reduce the squelch threshold setting on the
receiver.
sion (see page 25).
Adjust the input sensitivity (see page 25).