DuraSea Roof Top Air Conditioner
Description
Model
Air Conditioner
489516P
489516A
This Unit is designed for OEM installation.
Read these instructions carefully. These
instructions MUST stay with this product.
USA
SERVICE OFFICE
Dometic Corporation
1120 North Main Street
Elkhart, IN 46514
RECORD THIS INFORMATION FOR FUTURE
REFERENCE:
Model Number
Serial Number
ADB Model Number
ADB Serial Number
Date Purchased
Roof Top Unit
Use With Air Distribution Box (not included)
Model
3314860.000
3313189.049 Cool/Furn/HS White
CANADA
Dometic Corporation
46 Zatonski, Unit 3
Brantford, ON N3T 5L8
CANADA
Single Zone LCD
Electronic Control
SERVICE CENTER &
DEALER LOCATIONS
Please Visit:
www.eDometic.com

Advertisement

Table of Contents
loading

Summary of Contents for Dometic DuraSea 489516P

  • Page 1 REVISION B DEALER LOCATIONS SERVICE OFFICE Dometic Corporation Form No. 3315429.000 09/16 Dometic Corporation 46 Zatonski, Unit 3 Please Visit: (French 3315825.000_B) 1120 North Main Street Brantford, ON N3T 5L8 www.eDometic.com ©2016 Dometic Corporation Elkhart, IN 46514 CANADA LaGrange, IN 46761...
  • Page 2: Table Of Contents

    This unit can be installed by one person with brief help from additional personnel. Use these instructions to ensure a properly installed, and properly functioning product. Dometic Corporation reserves the right to modify appearances and specifications without notice. TABLE OF CONTENTS INTRODUCTION ..................................2...
  • Page 3: Important Safety Instructions

    ● This product MUST be [installed / serviced] by a qualified service technician. ● Do NOT modify this product in any way. Modifica- tion can be extremely hazardous. ● Do NOT add any devices or accessories to this product except those specifically authorized in writing by Dometic Corporation.
  • Page 4: Specifications

    3.5 kW / 5.0 kW For wire length over 24 ft., consult the National Electrical Code for proper sizing. ** Dometic Marine gives GENERAL guidelines for generator requirements. To reduce start-up power draw by up to 65%, consider installing a Dometic SmartStart.
  • Page 5: Installation Instructions

    INSTALLATION INSTRUCTIONS Choosing Proper Location For Unit c. Check inside the boat's cabin for air distri- bution box (hereinafter referred to as "ADB") This unit is specifically designed for installation on the roof obstructions (i.e. space for doors to open, of a boat.
  • Page 6: Wiring Requirements

    INSTALLATION INSTRUCTIONS Using the roof opening as a guide, cut the match- 2. Route a dedicated 12 Vdc supply wire (18-22) ing hole in the ceiling. AWG) from the boat converter (filtered side) or battery to the roof opening. The opening created must be framed to provide 3.
  • Page 7: Placing Unit On Roof

    INSTALLATION INSTRUCTIONS 4. Place the ADB kit (ordered separately) inside FIG. 4 the boat. These boxes contain mounting hard- ware for the unit and will be used inside the boat.  T his completes the outside work. Minor adjustments can be done from inside the boat if required.
  • Page 8: 120 Vac Power Supply Connection

    INSTALLATION INSTRUCTIONS 120 Vac Power Supply Connection Duct Divider Installation 1.  M easure the ceiling thickness. See (FIG. 8). 1.   ELECTRICAL SHOCK HAZARD. Verify 120 Vac power is disconnected from boat. 2. Cut away the number of rows as indicated in Failure to obey this warning could result in death table below.
  • Page 9: Low Voltage Wire Connections

    INSTALLATION INSTRUCTIONS Low Voltage Wire Connections Installing Unit 1.  I nstall the electronic control box. Make sure all  Verify the positive (+) 12 Vdc termi- wiring has been completed and that the elec- nal is disconnected from supply battery. Otherwise, tronic control box cover has been installed.
  • Page 10: Installing Adb

    INSTALLATION INSTRUCTIONS Installing ADB b. Hold the ceiling template up to the roof open- ing and start each mounting bolt by hand, 1.  A lign ADB with ceiling template. See (FIG. 16) through the ceiling template and up into the &...
  • Page 11 INSTALLATION INSTRUCTIONS 4. Install front and rear doors. FIG. 17 Hole In Ceiling 5. Place filter into return air vent grille. It may al- Template ready be installed on some units. See (FIG. 19). ADB Hole Alignment FIG. 19 Filter Hole In ADB Cover Return Air...
  • Page 12: General Information

    ● Go to WWW.dometic.com/marinedealers or ● Check your fuse or circuit breaker to see if it is ● Call Dometic Marine at 1-800-542-2477 8:00 open. Insure fuse is not burnt, or circuit breaker AM to 5:00 PM Eastern Time, or 1-888-440- is “ON”...
  • Page 13: Wiring Diagram

    WIRING DIAGRAM Unit Wiring Diagram FIG. 21 Electronic Control Kit Wiring Diagram FIG. 22...
  • Page 14: Owner's Limited Warranty

    Dometic reserves the right to improve its products, through changes in design or material without being obligated to incorporate such changes in products of prior manufacture. Dometic can make changes at any time in design, materials, or part of units of any one, model year, without obligation or liability to owners of units of the same year's model of prior manufacture.
  • Page 15: Coverage Period

    Dometic warranty as described in Section A. For proof of date put in service, Dometic will require a copy of the bill of sale of the Dometic equipment from the installer or new boat dealer to the original owner.
  • Page 16: Table Of Warranty Periods

    ABLE ARRANTY ERIODS DOMETIC DURASEA ROOFTOP AIR CONDITIONING Important Notes: 1. Warranty periods begin from the date of possession of the boat by the first owner if OEM installed or date of installation if dealer installed, but not to exceed three (3) years from date of production. The warranty is transferable and will carry the remainder of the original owner's warranty based on the original date of pur- chase or date of installation.