11. Start-Stop or Continuous Operation
Start-Stop is provided to reduce fuel consumption. This feature allows full
automatic control of the unit starting and stopping by monitoring compartment
temperature, battery charge condition and engine coolant temperature. The
main function of Start-Stop Operation is to turn off the refrigeration system near
setpoint to provide an efficient temperature control system and to initiate a
restart sequence after certain conditions are met.
1
2
1. With the system powered up (START/RUN-OFF switch in the START/
RUN position) press the START-STOP/CONTINUOUS key until the
desired operation (Start/Stop or Continuous) is highlighted.
2. "START/STOP MODE SELECTED" or "CONTINUOUS RUN MODE
SELECTED" will be displayed in the MessageCenter for 10 seconds.
3. The operation indication in the status bar will no longer be highlighted. The
unit is now running in the displayed mode.
If "CONTINUOUS LOCKED" or "START/STOP LOCKED" is dis-
played, the system is currently locked into the displayed mode of
operation and cannot be changed using the "START/STOP -
CONTINUOUS" key.
START/STOP
DIESEL
34
.3 34
BOX TEMPERATURE
START/STOP MODE SELECTED
NOTE
19
COOL
o
o
F
SETPOINT
F
62-11644