12. Data Recorder / Trip Start

The Data Recorder records data while the START/RUN - OFF switch is in the
START/RUN position.
1
2
1. With the system powered up (START/RUN-OFF switch in the START/
RUN position) press the MENU key until DATA RECORDER is displayed.
2. Press the DATA RECORDER soft key to display the sub menus.
MARK TRIP START
PRINT TO SCREEN
PRINT TO PRINTER
SCREEN SETUP
PRINTER SETUP
3. The Data Recorder screen will display with a 15-second timeout. Press the
▲ or ▼ key to scroll through the available sub menus. With the desired
sub-menu highlighted, press the "=" key to enter the menu.
12.1
Mark Trip Start
Trip Start places the present time and date as a stamp in the data recorder
memory to allow easy review of the data from the last trip, and to allow
downloading data from a specific trip. A trip begins at a Trip Start and ends at
the next Trip Start.
START/STOP
Viewing Menu Soft Key
Press Menu Key to Scroll
LANGUAGE
DATA
RECORDER
DATA RECORDER (1 of 5)
BACK
DIESEL
COOL
Selections
Choices vary based
on software revision
and model type.
EXIT