QK ^a^mq^qflk=ql=afccbobkq=qvmbp=lc=d^p=
Before performing any cleaning or maintenance work, disconnect the
appliance from the mains.
The hob of the cooker is adjusted for use with either natural gas at a
pressure of 1.0kPa (SA 9066 – SA 9065) or LPG (liquid petroleum gas)
at a pressure of 2.75 kPa (SA 9066 LPG – SA 9065 LPG). If used with
other types of gas, you have to replace the nozzles, then adjust the
minimum flame on the gas taps. For nozzle replacement and burner
adjustment operate as described in the following paragraph.
QKN
This operation requires no primary air regulation.
1.
Extract the grids and remove all the caps and flame-spreader
crowns;
2.
unscrew the burner nozzles with a 7 mm socket wrench;
3.
replace the nozzles according to the type of gas to be used and the
description in paragraph "4.2 Burner and nozzle characteristics
table".
4.
Replace the burners in the correct position.
10
Instructions for the installer
oÉéä~ÅÉãÉåí=çÑ=åçòòäÉë=çå=íÜÉ=ÜçÄ=