ELECTRODE CONNECTION

The LN-25™ PIPE (CCC) does not include the elec-
trode cable. The customer is to install an AWG 2/0 to
4/0 cable.
To install:
1. Turn off power at the welding power source.
2. With a 5/16" nutdriver, remove the 4 screws holding
the rear cover panel. Lift out the cover panel.
FIGURE A.10
3. Using a 3/4" open end wrench, loosen the bolt for
the electrode lead connection.
FIGURE A.11
Use 3/4" open end wrench to loosen here.
INSTALLATION
4. Route the electrode lead through the feeder as
shown.
5. Assemble the bolt, leads and washers as shown.
Discard the extra washers.
6. Reassemble the rear cover panel and tighten the 4
screws.
4 SCREWS
BOLT
LOCK WASHER
WASHER
67 LEAD
7. Tighten the strain relief.
LN-25™ PIPE
FIGURE A.12
ELECTRODE LEAD
Route the electrode through the opening this way.
FIGURE A.12
TIGHTEN HERE
A-9