Instructions for Use 8MP 55" LCD-Monitor Important Please read the safety information and all information delivered with the product carefully to familiarize yourself with safe and effective usage.
Use of EIZO products WARNING EIZO products may only be used for the applications described in the catalog and in the relevant tech- nical documentation. If products and components from other manufacturers are used, these must be recommended or approved by EIZO. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
1.2 Intended use Intended purpose The CuratOR LL550W is intended for the display of still images and moving images from various commercially available devices commonly used in a medical environment, in partic- ular radiology. The monitor is optimized for the reproduction of grayscale X-ray images. The monitor is not suitable for mammography.
2 Safety information 2.1 General safety instructions Correct and safe operation of EIZO devices assume professional transport, storage, installa- tion, and connection, as well as careful operation and service. The devices may only be used for applications for which they are intended.
Page 8
Only use power cables approved for China. These power cables are identified by the labels "CCC" or "CQC". Observe the country-specific regulations Observe all regulations of the country in which the device is used. CuratOR LL550W Instructions for Use, 02/2024...
Page 9
If the device is brought into a room with a higher or rising temperature, condensed water will form in and on the device. Do not switch on the device until the condensed water has evaporated. Other- wise, the device could be damaged. CuratOR LL550W Instructions for Use, 02/2024...
Page 10
Note that monitors can fail as a result of aging, and that image properties such as brightness, con- trast,and color value can change. Do not touch the monitor screen Due to mechanical pressure or electrostatic discharges, touching the screen can result in brief distur- bances to the image. CuratOR LL550W Instructions for Use, 02/2024...
Note Image quality To maintain constant image quality, EIZO recommends cleaning the monitor on a regular basis and checking image properties in accordance with all applicable local regulations. CuratOR LL550W Instructions for Use, 02/2024...
Note Keep the packaging material for subsequent transport of the device. Device The CuratOR LL550W is a LCD Monitor for mounting in a ceiling suspension unit or wall mount. Product Order number...
(LUTs) have been preset. This calibration data makes installation and maintenance easier. As such, the monitor can be easily adapted to the respective application and local lighting conditions. 3.3 Medical subsystem The CuratOR LL550W can be part of a medical subsystem comprising the following compo- nents. Mandatory Devices •...
In the worst case, deposits are possible which become evident as dark spots in a white picture and result in deterioration of the luminance. • Protect the monitor from dust, for example through appropriate construction measures at the installation site. CuratOR LL550W Instructions for Use, 02/2024...
Page 15
If the monitor is installed such that it can move, make sure that persons or objects in the facility are not endangered by the monitor's range of movement. Note During transport, use the original packaging or service packaging. CuratOR LL550W Instructions for Use, 02/2024...
1. Carefully open the packaging and remove the upper section of the carton as well as all accessible packing parts. 2. Lift the monitor from the base of the packing carton. Hold it on the side and underside. CuratOR LL550W Instructions for Use, 02/2024...
• Holders must be tested and approved by the manufacturer for the weight to be sup- ported. • An installed stand must be sufficiently stable such that tilting up to 10° does not result in the monitor toppling. CuratOR LL550W Instructions for Use, 02/2024...
Device settings may only be adjusted by service personnel. NOTICE Disconnecting from line power Always set the power switch to "Off" before disconnecting the device from power. Other- wise the device could be destroyed. CuratOR LL550W Instructions for Use, 02/2024...
Means of isolating the device from mains supply is by disconnecting the AC power line. • Make sure that the AC power line is easily accessible. Power connector USB A (not shown) Fig.: Lower connection panel CuratOR LL550W Instructions for Use, 02/2024...
Page 20
• Only service can connect or disconnect a photometer. • Only photometers tested for calibrating the monitor may be connected to the serial inter- face. • A photometer must not be connected in the presence of the patient. CuratOR LL550W Instructions for Use, 02/2024...
4. Secure appliance cable with cable ties to the lug to prevent unintentional loosening (marked with a circle). 5. Insert the DVI cable directly into the DVI socket. Only Dual Link DVI cables of a corre- spondingly high quality may be used. CuratOR LL550W Instructions for Use, 02/2024...
Page 22
Connecting 5.3 Description of connection procedure 6. If TDL3600-QL modules from EIZO are used: Connect the CAT cables to the DVI receiver module connectors and tighten the clamps. When connecting the cables, observe the color coding and customer-specific informa- tion.
Use a screen saver with regularly changing images • Switch off the monitor when it is no longer needed. • The monitor has an energy saving mode: If the application in use supports the energy saving mode, activate it. CuratOR LL550W Instructions for Use, 02/2024...
6.4 Check for pixel defects Pixel defects (small bright or dark dots) can occur in LCD monitors. During the manufactur- ing process, all monitors are checked for the permitted number of defective pixels. Defective pixels cannot be corrected. CuratOR LL550W Instructions for Use, 02/2024...
Measures in the event of a failure Note Device malfunction in operation If the device is not working properly, check the system for basic connection and operating errors before contacting service personnel. CuratOR LL550W Instructions for Use, 02/2024...
The picture quality of the monitor changes due to aging of the LCD unit and the backlight. • Check the monitor settings at regular intervals in accordance with the local guidelines. • Correct the settings if necessary. CuratOR LL550W Instructions for Use, 02/2024...
Lamp warm-up period: Inform servicing department Setting is active, and the warm-up pe- riod has expired without the monitor having reached the stabilized lumi- nance level. Internal error Inform servicing department CuratOR LL550W Instructions for Use, 02/2024...
- 3840 x 2160 (4K UHD) at 60 Hz Service and communication over DDC of DVI socket B USB A, USB B Service or software update Mini-DIN 6 socket (serial connection) Service or connecting a photometer CuratOR LL550W Instructions for Use, 02/2024...
700 hPa to 1060 hPa Humidity 10% to 80%, non-condensing Transport and storage (packed) Temperature range -20°C to +55°C ambient temperature Temperature gradient Max. 5 °C/h, no condensation Air pressure 500 hPa to 1060 hPa Humidity 10% to 90%, non-condensing CuratOR LL550W Instructions for Use, 02/2024...
USA: National Standard AAMI ES60601-1 • UK: BS EN 60601 • China: GB4943.1 (non-tropical, altitude< 2000 m), Safety specification T6.3AH, 250 V Protection class Protection class I Degree of protection IP20 Medical device classification (EU) Class 1 CuratOR LL550W Instructions for Use, 02/2024...
Dimension drawings 11.1 Monitor dimensions 11 Dimension drawings All dimensions in mm 11.1 Monitor dimensions Front view View from behind and to the side - with cover CuratOR LL550W Instructions for Use, 02/2024...
Symbol for degree of protection according to DIN EN 60529. "On" symbol (voltage). "Off" symbol (voltage) Input for service calls. Symbol for "Comply with the instructions for use". Symbol for "Dangerous voltage". UK Responsible Person Swiss authorised representative (CH-REP) CuratOR LL550W Instructions for Use, 02/2024...
IEC 60601-1-2. Electromagnetic radiation The CuratOR LL550W is intended for use in the electromagnetic environments noted below. Operators or users of the CuratOR LL550W have to ensure that the device is used in such an environment. Radiation test...
Page 35
The CuratOR LL550W was tested with the following compliance levels in accordance with the test requirements for professional healthcare facilities, as established in IEC 60610-1-2. Operators or users of the CuratOR LL550W have to ensure that the monitor is used in such an environment.
Page 36
• The ISM bands between 150 kHz and 80 MHz are 6.765 MHz to 6.795 MHz, 13.553 MHz to 13.567 MHz, 26.957 MHz to 27.283 MHz, and 40.66 MHz to 40.70 MHz. CuratOR LL550W Instructions for Use, 02/2024...
Page 37
CuratOR LL550W based on the output power of the transmitter The CuratOR LL550W is intended for use in an electromagnetic environment in which inter- ference due to electromagnetic radiation is controlled. For other portable and mobile RF...
Page 38
For some radio services, only the frequencies for the radio contact from the mobile communica- tions device to the base station ("uplink") is included in the table. The carrier is modulated by a square wave with 50% duty cycle. CuratOR LL550W Instructions for Use, 02/2024...
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Note Use the specified cable below or EIZO signal cable with this monitor so as to keep interference within the limits of a Class B digital device. •...
EFUP shall be done in accordance with the Product Maintenance Procedures. This product must not be disposed of as unsorted municipal waste, and must be col- lected separately and handled properly after decommissioning. CuratOR LL550W Instructions for Use, 02/2024...
Page 41
Applications of hazardous substances in this medical device are required to achieve its intended clinical uses, and/or to provide better protection to human beings and/or to environment, due to lack of reasonably (economically or technically) available substitutes. 产品中有毒有害物质或元素的名称及含量 Table of hazardous substances’ name and con- centration. CuratOR LL550W Instructions for Use, 02/2024...
12.9 Repairs Please contact the sales partner from whom you purchased the product. The repair may only be carried out directly at EIZO or at a location expressly authorized by EIZO for this purpose. 12.10 Contact Support during installation and for technical questions www.eizo-or.com...
ENERGY STAR is a registered trademark of the United States Environmental Protection Agency in the United States and other countries. EIZO, the EIZO Logo, ColorEdge, CuratOR, DuraVision, FlexScan, FORIS, RadiCS, Radi- Force, RadiNET, Raptor and ScreenManager are registered trademarks of EIZO Corpora- tion in Japan and other countries.