7.2 Indoor Unit Error Display

For All models(Wall mounted(Hi-Wall) series, Duct/Cassette/ Floor Ceiling):
Timer
Operation lamp
lamp
★ 1 time
X
★ 2 times
X
★ 4 times
X
★ 5 times
X
★ 6 times
X
★ 8 times
X
★ 1 times
★ 2 times
★ 3 times
★ 4 times
★ 5 times
★ 6 times
★ 7 times
★ 8 times
★ 9 times
★ 10 times
★ 1 times
★ 2 times
★ 3 times
★4 times
★ 5 times
★ 6 times
★ 7 times

7.3 Outdoor Unit Display

7.3.1 Outdoor Unit Point Check Function
A check switch is included on the outdoor PCB.
Display
LED STATUS
E0
Indoor unit EEPROM parameter error
E1
Communication malfunction between indoor and outdoor units
E3
Indoor fan speed malfunction
E4
Indoor room temperature sensor (T1 ) malfunction
Evaporator coil temperature sensor (T2) malfunction
E5
EE
Water-level alarm malfunction
F0
Current overload protection
F1
Outdoor ambient temperature sensor (T4 ) malfunction
F2
Condenser coil temperature sensor (T3) malfunction
F3
Compressor discharge temperature sensor (T5) malfunction
F4
Outdoor unit EEPROM parameter error
F5
Outdoor fan speed malfunction
Indoor coil outlet pipe sensor(Located on outdoor unit low pressure
F6
valve)
Communication malfunction between Cassette optional lift panel
F7
and the unit.
F8
Cassette optional lift panel malfunction
F9
Cassette optional lift panel not closed
P0
Inverter module (IPM) malfunction
P1
Over-voltage or under-voltage protection
High temperature protection of compressor top(OLP)/ High
P2
temperature protection of IPM board
P3
Low ambient temperature protection
P4
Compressor drive malfunction
P5
Indoor units mode conflict
(——)
P6
Low pressure protection
★ flash ,  light, X extinguished
28
ODU
Error
——
E2
——
——
——
——
E4
E4
E4
E0
E8
——
——
——
——
P6
E5
——
LP
——
——
P2