Operation
Mnemonic Op Code Format
Operands
Description
Interruptions
Cond Code
OR
OR
16
RR
Rl,R2
The ORed sum of both opr's into opr 1
None
0 Result= 0
1 Result
f:.
0
OR
OJ
96
SI
Dl(Bl),12
OR the 1 byte from the instruction stream
Prot
0 Result= 0
(8-15) to opr 2
Adr
1
Result~
0
Pack
PACK
F2
SS
Dl(Ll,Bl),
Change opr 2 from zoned to packed format
Prot
Unchanged
D2(L2, B2)
and place into opr 1.
Adr
(Right to left byte by byte)
(No restriction on overlapping fields)
(Opr 2 may be extended with hi-order zeros
if opr I too long, thereby inserting zeros in
opr 1.)
Ix ID Is ID I
I D I D Is I
Read Direct
RDD
85
SI
D!(Bl), I2
The 1 byte from the instruction stream
Privileged
Unchanged
(8-15) is placed on the timing-signal bus-
Oper
out, in a form of 8 timing pulses, along with
Prot
a 9th pulse at the read-out line. The 8 bit
Adr
lines at the direct-control bus-in lines are
stored in opr 1.
Set Program Mask
SPM
04
RR
Rl
Opr I (2-7) replaces the cond code and
None
Set by bits
program mask bits of the current PSW
2 and 3
(34-39)
(Bits 0, 1 and 8-31 are ignored and
unchanged.)
Set Storage Key
SSK
08
RR
Rl,R2
Opr 1 (24-27) replaces the storage key
Privileged
Unchanged
specified by the opr 2
Oper
(Opr 1 bits 0-23 and 28-31 are ignored)
Adr
(Opr 2 bits 0-7 and 21-27 are ignored)
Spec
(Bits 28-31 must be zero)
Set System Mask
SSM
80
SI
Dl(Bl)
Opr 1 (1 byte) replaces the system mask
Privileged
Unchanged
bits of the current PSW (0-7 ).
Oper Adr

Advertisement