Operation
Mnemonic Op Code Format
Operands
Description
Interruptions
Cond Code
Load Positive
LPR
10
RR
Rl,R2
Opr 2 into opr 1
Exp Olio
0 Result= 0
(Negative numbers are complemented)
(Overflow.occurs when the max negative
2
Result > 0
number is complemented)
3 Overflow
Load Positive (Long)
LPDR
20
RR
Rl,R2
Opr 2 into opr 1
Spec
Result
(FPR)
(FPR)
0
Fract = 0
(Both opr's made positive)
2
Result > 0
Load Positive (Short)
LPER
30
RR
R!,R2
f'C>Pr 2 into opr 1
Spec
Result
(Both opr's made positive)
0
Fract = 0
(Low-order half of opr 1 unchanged}
2 Result > 0
Load PSW
LPSW
82
SI
D!(Bl)
Opr 1 into PSW
Privileged
Set by new
(Opr 1 low-order 3 bit adr must
=
0)
Oper
PSW 34 and
(Instruction used to enter the problem or
35
wait state)
Load (Short)
LE
78
RX
RI, D2(X2, B2)
Opr 2 into opr 1
Adr
Unchanged
(Sto)
(FPR)
Spec
(Low-order half of opr 1 unchanged)
Load (Short)
LER
38
RR
R!,R2
Opr 2 into opr 1
Spec
Unchanged
(FPR)
(FPR)
(Low-order half of opr 1 unchanged)
Move
MVC
D2
SS
Dl(L, Bl), D2(B2)
Opr 2 to opr 1
Prat
Unchanged
(Left to right byte by byte)
Adr
(Max number of bytes moved: 256)
(No restriction on overlapping fields)
Move
MVI
92
SI
D!(Bl), 12
Move the 1 byte from the instruction
1
Prat
Unchanged
stream (8-15) to opr 2