Operational Status Messages

The LCD screen displays a range of status and diagnostic messages, depending on the operating conditions. The
following status messages, will be shown in pool, spa, and remote modes when no active fault conditions are present.
Display
Demand has been satisfied and the unit is in standby.
No Demand
Unit is operating and running a heating cycle.
Heating
Unit is operating and running a cooling cycle.
Cooling
Unit is performing a defrost cycle. Coil temperature is below defrost temperature limit. Verify defrost
Defrost
temperature and defrost deadband settings.
Comp Start Delay
Notification that the compressor is under a 3-minute delay before turning on.
Notification that the 3-way valves are being commanded to change positions
Valve Chng Delay
pool to spa, or spa to pool.
The solar heating setting is enabled, and running with the heat pump.
Solar Heat
The compressor is not running because the ambient temperature is too cold as measured by the
Outside Lockout
ambient sensor. Verify outside lockout temperature setting.
28
Condition
Table D.