About Stop Panel

No
Name
.
1
SOURCE light
2
LOW OIL PRESS light
3
OVER SPEED light
4
HIGH WATER TEMP light
5
F.O. LEAK light
6
TRIP CANCEL light
7
Warning bell
8
Warning light
9
SOURCE switch
10 ENGINE STOP button
11 RESET button
12 BELL STOP / ALARM TEST button
13 TRIP CANCEL switch
1
2
3
4
5
6
ENGINE ALARM PANEL
LOW
HIGH
OVER
F. O.
TRIP
SOURCE
OIL
WATER
SPEED
LEAX
CANCEL
TEMP
PRESS
SOURCE
ENGINE STOP
RESET
BELL STOP
TRIP CANCEL
ON
ON
OFF
OFF
ALRARM TEST
9
10
11
12
13

Fig. 2-15 Stop Panel

Table 2-2 About Stop Panel

The light comes on when the instrument panel power is turned on.
Engine stops and light comes on when there is abnormal engine oil
pressure drop. (Oil pressure that triggers the switch: 0.15 MPa
2
{1.5 kgf/cm
} [21.8 psi] )
Engine stops and light comes on when the engine is overspeeded.
-1
(1888 min
)
Engine stops and light comes on when the coolant temperature rises
abnormally.
(Temperature at which thermo switch turns ON: 98°C [208°F])
The light comes on when fuel leak occurs.
The light comes on when the trip function is cancelled.
This warning bell will ring when an abnormal condition occurs.
This warning light will come on when an abnormal condition occurs.
Turn this switch to ON position to activate the instrument panel.
The engine stops when this button is pressed.
Press "RESET" button to start the engine again after an abnormal
stop.
To check operation of stop panel, press down this lever while the
starter switch is on. All warning lights will glow. Check this during
start-up inspection. When warming bell rings, raise the lever to stop
the bell ringing.
TRIP function can be cancelled temporarily by turning this switch to
ON position.
Chapter 2 NAME OF PARTS
7
8
Function
2-9