Table 8-1 Specific Gravity Of Electrolyte - Mitsubishi S12R-T2MPTK Operation & Maintenance Manual

Table of Contents

Advertisement

Specific Gravity of Battery Electrolyte - Check
If the specific gravity measured at 20 °C [68 °F] is
lower than 1.22, charge the battery.

Table 8-1 Specific Gravity of Electrolyte

Specific gravity
at 20 °C [68 °F]
From 1.26 to 1.28
Fully charged
From 1.22 to 1.26
Less than 1.22
Discharged
Chapter 8 PERIODIC INSPECTION AND MAINTENANCE PROCEDURES
Conditions
Remedy
-
Partially
Charge
charged
Charge
Float
Electrolyte
surface
Electrolyte
Glass tube
Fig. 8-34 Specific Gravity of Battery Electrolyte -
Check
8-25