Table 2. DSX-1 Interface Options – Model 7974
Line Coding
Possible Settings: AMI, B8ZS
Default Setting: B8ZS
Specifies the line coding format to be used by the DSX-1 interface.
Line Framing
Possible Settings: ESF, D4
Default Setting: ESF
Specifies the framing format to be used by the DSX-1 interface.
Line Equalization
Possible Settings: 0–133, 133–266, 266–399, 399–533, 533–655
Default Setting: 0–133
Compensates for signal distortion for a DSX-1 signal over a given distance.
Excessive Error Rate Threshold
Possible Settings: 1E–4, 1E–5, 1E–6, 1E–7, 1E–8, 1E–9
Default Setting: 1E–4
Determines the error rate at which an excessive error rate (EER) condition is
recognized. The rate is the ratio of the number of CRC errors to the number of bits
received in a certain period.
Send (AIS) on Network Failure
Possible Settings: Enable, Disable
Default Setting: Enable
Specifies the action taken on the signal transmitted to the DSX when a valid signal
cannot be recovered from the network interface (LOS or cognitions OOF, AIS, or
EER).
Primary Clock Source
Possible Settings: DSX, Internal
Default Setting: Internal
When configured as the LTU, specifies from where the unit will derive its timing.