4.8.1.7. User Objects
It can store up to 60 used entered objects, including comets.
4.8.1.8. Enter R.A. DEC
Here you can go to a target by entering its R.A. and DEC numbers.

4.8.2. Sync to Target

This operation will match the telescope's current coordinates to Target Right Ascension and
Declination. After slewing to an object, press MENU => "Sync to Target" => ENTER. Follow the screen to
perform the sync. Using this function will re-calibrate the computer to the selected object.
"Sync to Target" will only work after "Select and Slew" is performed. You can change the slewing
speed to make the centering procedure easier. Simply press a number (1 through 9) to change the speed.
The default slew speed is 64X.

4.8.3. Alignment

Pole Star Position
4.8.3.1.
This function displays the position of the Pole Star for Quick Polar Alignment using the iOptron
TM
AccuAlign
polar scope. In the Northern Hemisphere the position of Polaris is displayed, while in the
Southern Hemisphere the position of Sigma Octantis is shown.
Polar Iterate Align
4.8.3.2.
This alignment method allows you to polar align the mount even if you cannot view the Celestial
Pole. Press the MENU => "Alignment" => "Polar Iterate Align". The HC will display a list of bright
alignment stars near the meridian as Alignment Star A. Follow the HC instructions to move Alignment Star A
to the center of the eyepiece using a combination of the Latitude Adjustment Knob and the "◄" and "►"
buttons. Press ENTER to confirm the settings. Next, select a bright star that is close to the horizon as
Alignment Star B. Center it using the Azimuth Adjustment Knobs and the "◄" and "►" buttons (the "
and "
▼"
buttons will not function). Press ENTER to confirm the settings.
The telescope will now slew back to Alignment Star A to repeat the above steps. The iteration can
be stopped when it is determined that the alignment error has been minimized. Press the BACK button to
exit the alignment procedure.
NOTE: It is highly recommended to use an eyepiece with illuminated crosshairs for accurate
centering.
NOTE: The movement of the alignment star in your eyepiece may not be perpendicular depending
on its location in the sky.

4.8.4. Settings

4.8.4.1. Set Time and Site
Refer to 4.4 Set up Handset.
4.8.4.2. Set Beep
The handset allows a user to turn off the beep partially, or even go to a silent mode. To change this
setting press MENU => "Settings" => "Set Beep",