Diagnostic (External Dbu) Configuration Options; Diagnostic (General) Configuration Options - Paradyne COMSPHERE 3550 Series User Manual

Data service units
Hide thumbs Also See for COMSPHERE 3550 Series:
Table of Contents

Advertisement

COMSPHERE 3550 Series Data Service Units
Diag Type: Disr
Next
Disr
None
Diagnostic Type . This configuration option defines the diagnostic interaction between control and tributary DSUs that are
in backup using an external dial backup unit (DBU). All DSUs on the same circuit should be set the same (e.g., if the
control is set to Disr, all its tributaries should also be set to Disr).
Disr
Select disruptive diagnostics for diagnostic data to be carried between the control and the tributary DSUs
over the same (primary) channel as user-transmitted data. User-initiated commands are sent between the
control and the tributary DSUs disruptively, interrupting data.
None
Select none if only local diagnostics are to be allowed; that is, there will be no diagnostic communications
with remote devices.
Position: Cntrl or Trib
Next
Cntrl
Trib
Network Position . This configuration option determines the DSU's position in the network, as well as its test and
diagnostic capabilities.
Cntrl
Select if the DSU is a control (PTPC or MPTC configuration).
Trib
Select if the DSU is a tributary (PTPT or MPTT configuration).
LinkConfig: Pt-Pt or M-Pt
Next
Pt-Pt
M-Pt
Link Configuration . Used to define a point-to-point or multipoint circuit, this configuration option is required for proper
testing, dial backup, unit operation, and is required when using nondisruptive diagnostics.
Pt-Pt
Select for a point-to-point configuration (PTPC or PTPT configuration).
M-Pt
Select for a multipoint configuration (MPTC or MPTT configuration).
Resp Period: 1
Next
1
2
10
Response Period (only displayed when any Diag Type is set to NonD or Mixed, LinkConfig is set to M-Pt, and Full Mode
is enabled). Used for single-port multipoint applications and applicable to tributary DSUs and DBMs only. This
configuration option determines how often health and status messages are transmitted, which are transmitted each time
the Request-to-Send (RTS) lead is raised.
1
Select if you want the tributary DSU to transmit health and status information every time RTS is raised
( not applicable for PTPC, PTCT, or MPTC configurations).
2
Select if you want the tributary DSU to transmit health and status information every other time that RTS is
raised.
10
Select if you want the tributary DSU to transmit health and status information every 10th time that RTS is
raised.
5-10
Table 5-4

Diagnostic (External DBU) Configuration Options

Prev
Table 5-5

Diagnostic (General) Configuration Options

Prev
Prev
Prev
(1 of 2)
July 1999
3550-A2-GB20-40