Diagnostic (Dbm) Configuration Options - Paradyne COMSPHERE 3550 Series User Manual

Data service units
Hide thumbs Also See for COMSPHERE 3550 Series:
Table of Contents

Advertisement

Diag Type: Disr
Next
NonD
Disr
Diagnostic Type . This configuration option defines the diagnostic interaction between control and tributary DSUs that are
in backup. All DSUs on the same circuit should be set the same (e.g., if the control is set to NonD, all its tributaries
should also be set to NonD).
NonD
Select nondisruptive diagnostics for diagnostic data to be transmitted between the control and the
tributary DSUs over a separate diagnostic channel.
Disr
Select disruptive diagnostics for diagnostic data to be carried between the control and the tributary DSUs
over the same (primary) channel as user-transmitted data. User-initiated commands are sent between the
control and the tributary DSUs disruptively, interrupting data.
Mixed
Select if operating over a multipoint network. This setting supports nondisruptive health and status
updates, but user-initiated commands are sent between the control and the tributary DSUs disruptively,
interrupting data.
None
Select none if only local diagnostics are to be allowed; that is, there will be no diagnostic communications
with remote devices.
2nd Ch(bps): 400
Next
100
400
In-band Secondary Channel Diagnostic Transport Speed in bps (only displayed when Diag Type is set to NonD and Full
Mode is enabled). This configuration option allocates the DBM's port bandwidth when there is no excess bandwidth
available for in-band secondary channel transport (used for diagnostic data) operation.
How to Select Bandwidth: Select one of the valid diagnostic speeds from the table below for the DBM's port and the
DBM's rate, as specified in the Rate(Kbps) configuration option under the DBM option set. (Example: If the DBM's
Rate(Kbps) configuration option is set to 9.6 kbps, you can select 100, 400, 800, 1200, or 1600. If you select 400, the
resulting DBM port speed will be 9.2 kbps.)
NOTE: When The TDM/Flex is operating at a line rate greater than 19.2 kbps or with a multipoint configuration,
100 bps is not a valid in-band secondary channel transport rate.
If the DBM Rate(Kbps) is equal to Port Speed, or
if the underspeed port speed and sum of the
TDM/Flex ports is equal to the
aggregate speed on the DBM:
1.2
2.4
4.8
9.6
12.0
14.4
3550-A2-GB20-40
Table 5-3

Diagnostic (DBM) Configuration Options

Mixed
None
Prev
800
1200
1600
Valid diagnostic speeds are:
Prev
100, 400
100, 400, 800
100, 400, 800, 1200, 1600
100, 400, 800, 1200, 1600
100, 400, 800, 1200
100, 400, 800, 1200, 1600
July 1999
Configuring the Unit
5-9

Advertisement

Table of Contents
loading

This manual is also suitable for:

3551Comsphere 3550Comsphere 3551

Table of Contents