Siemens 6SL3120-2TE21-0AA3 Manual page 426

Booksize power units
Table of Contents

Advertisement

External air cooling
Max. ambient temperature
without derating
with derating
Sound pressure level
Cooling air requirement
Max. permissible heat sink
temperature
Weight
Default for 400 V line systems; undervoltage trip threshold can be reduced by up to 80 V (exception: 132 A and 200 A
1)
Motor Modules) and is adjusted to the parameterized rated voltage.
Rated power of a typical standard induction motor at 400 V 3 AC.
2)
Booksize Power Units
Manual, (GH2), 04/2014, 6SL3097-4AC00-0BP6
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
6SL3121– 1TE24-5AAx
° C
° C
dB(A)
< 65
m
/h
112
3
° C
85
kg
13,2
6.3 Motor Module with external air cooling
1TE26-0AAx
1TE28-5AAx
40
55
< 65
< 60
112
160
90
88
13,3
17,2
Motor Modules Booksize
1TE31-3AAx
1TE32-0AAx
< 73
< 73
520
520
73
80
(70%
derating)
27,1
28
425

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics s120

Table of Contents