Table of Contents

Advertisement

Troubleshooting
Problem
Items to check
The buttons of the
Could you have enabled the "Panel
operating panel do not
Lock" setting to prevent inadvertent
work
operation?
The volume level of the
Could the volume of the connected device be turned down?
unit connected to Input
Could "Input/Bluetooth Vol. " be lowered?
jack is too low
° Error Messages
Indication
Meaning
An error occurred during writing. The USB flash drive may be corrupted.
Insert other USB flash drive and try again. Alternatively, you can initialize the USB flash drive ("Initializing the Memory
Error 2
(Format Media)" (p. 24)).
The internal memory might be damaged. Format the internal memory ("Initializing the Memory (Format Media)" (p. 24)).
Error 3
The same file already exists.
No USB flash drive is inserted. Insert the USB flash drive and try again.
Error 10
The internal memory might be damaged. Format the internal memory ("Initializing the Memory (Format Media)" (p. 24)).
There is not sufficient free memory in the save destination.
Error 11
Either insert other USB flash drive or delete unneeded files and try again.
An error occurred during reading. The USB flash drive may be corrupted.
Insert other USB flash drive and try again. Alternatively, you can initialize the USB flash drive ("Initializing the Memory
Error 14
(Format Media)" (p. 24)).
The internal memory might be damaged. Format the internal memory ("Initializing the Memory (Format Media)" (p. 24)).
Error 15
The file is unreadable. The data format is not compatible with the unit.
This audio format is not supported.
Error 18
Use an WAV format (44.1 kHz, 16-bit linear) or MP3 format audio file.
Error 30
Internal memory capacity of the unit is full.
The unit cannot deal with the excessive MIDI data sent from the external MIDI device.
Error 40
Reduce the amount of MIDI data sent to the unit.
Error 43
A MIDI transmission error has occurred. Check the connected MIDI device.
There may be a problem with the system. Repeat the procedure from the beginning. If it is not solved after you have tried several
Error 51
times, contact the Roland service center.
The USB Memory port was subjected to excessive current. Make sure that there is no problem with the USB flash drive, then turn
Error 65
the power off, then on again.
32
Cause/Action
Disengage the "Panel Lock" setting.
Page
p. 29
p. 25