Lincoln Electric INVERTEC 270SX Service Manual page 49

Hide thumbs Also See for INVERTEC 270SX:
Table of Contents

Advertisement

B
A
C
D
REMOVAL PROCEDURE
Necessary tools:
- Phillips screwdriver PH02
- A small flat bladed screwdriver (for A)
- 10mm wrench
1. Remove the thermostats harnesses (A), signal harness (B), Hall probe harness (C) and unscrew the power cables
(D)
2. Remove the insulation protection to have access to the nut (E) and remove it along with its related bolt.
F
3. Remove the nut (F) and its related bolt
4. Unscrew the 3 screws (G) and remove the orizontal copper bar
 
 
DISASSEMBLY OPERATIONS
OUTPUT BOARD REMOVAL AND REPLACEMENT PROCEDURE
W05X1043R for INVERTEC
 
Page 49
 
®
400SX
Pay attention to the
arrow direction on
the current sensor !
G
WARNING
Disconnect input power before servicing.
Do not operate with covers removed.
Do not touch electrically live parts.
Only qualified persons should install, use
ELECTRIC SHOCK
or service this equipment.
CAN KILL
E

Advertisement

Table of Contents
loading

This manual is also suitable for:

Invertec 400sx52077520785208152082

Table of Contents