C
REMOVAL PROCEDURE
Necessary tools:
- Phillips screwdriver PH02
- A small flat bladed screwdriver (for A)
- 10mm wrench
- 7mm nut driver
- 6mm nut driver
1. Remove the thermostats harnesses (A), signal harness (B) and unscrew the power cables (C)
2. Unscrew the nuts (D) and remove the related bolts.
3. Unscrew the 7 screws (E) that fix the second copper bar and remove it.
 
 
DISASSEMBLY OPERATIONS
OUTPUT BOARD REMOVAL AND REPLACEMENT PROCEDURE
W05X1044R for INVERTEC
 
Page 47
 
®
270SX
D
E
WARNING
Disconnect input power before servicing.
Do not operate with covers removed.
Do not touch electrically live parts.
Only qualified persons should install, use
ELECTRIC SHOCK
or service this equipment.
CAN KILL