7.4. Procedure for Adjustment
IMPORTANT (About 1st lens frame adjustment):
.
There are 2 kinds of methods to align the 1st lens frame unit for this lens unit.
Select one of the following method, then proceed it.
(If you choose one & performed it, skip another one.)
Simple Resolution Checker method
Projector method
7.4.1. 1st Lens Frame Adjustment (Simple Resolution Checker method)
7.4.1-1. Flow chart for Simple Resolution Checker method.
General description:
There are "Still mode" and "Real-time mode".
1) Still mode
:
2) Real-time mode : This mode is used for adjustment. Since adjusted result are reflected and displayed in
Setting for Simple Resolution Checker method
OK
the Electrical Adjustment section
P
C
This mode is used for inspection. This mode is also used for adjustment by repeating
"Taking a picture - Inspection - Adjustment" as a cycle.)
real time, it is able to adjust by monitoring the value.
After real time adjustment has been completed, perform inspection with single mode.
NOTE:
Since this model is a Zoom lens, perfom both "TELE edge" & "WIDE edge" at each steps.
Perform inspection
with
Still mode
(Check the brightness and settings
NG
of camera body and test chart in advance.)
Perform adjustment
with
Real-time mode
OK
Perform inspection
with
Still mode
OK
Move on to
☞
Move on to the
"7.4.1. 1st Lens Frame Adjustment
(Simple Resolution Checker method)"
☞
Move on to the
"7.4.2. 1st Lens Frame Adjustment
(Projector method)"
NG
NG
20
- Try again after
disassembly/assembly
NG
Perform adjustment
with
Still mode*1
OK
*1 :
Repeating "Taking a picture - Inspection
- Adjustment" as a cycle