Technical Data - Siemens SINAMICS S220 Equipment Manual

Booksize power units
Hide thumbs Also See for SINAMICS S220:
Table of Contents

Advertisement

8.5.5

Technical data

Technical data
Table 8-34
Single Motor Modules D type (85 A to 200 A)
Feature
Output data
Rated current (l
)
rated
Intermittent duty current (l
Peak current (l
)
max
Output voltage 3 AC
Output frequency
Apparent power for U
of 600 V
DC
Rated power IEC
3)
Rated power NEC
4)
Input data
DC link voltage (U
)
DC
Overvoltage trip
Undervoltage trip
5)
Electronics power supply
DC link current (I
)
DC link
DC link capacitance
Current-carrying capacity
DC link busbars
24 V DC busbars
Current consumption of the electronics
at 24 V DC
Power loss
Cooling air requirement
Weight
Cable lengths
In the case of overmodulation, a motor output voltage up to 3% higher is possible.
1)
Higher output frequencies up to a maximum of 3200 Hz are possible with an additional license.
2)
Rated power of a typical standard induction motor at 3 AC 400 V according to IEC 60947-4-1:2018 Annex G Table G.1
3)
4)
Rated power of a standard induction motor at 3 AC 460 V according to NEC Table 430.250
Depends on the parameterized device supply voltage
5)
Booksize power units
Equipment Manual, 09/2023, A5E53307519B AA
Unit
 
A
) 40 %
A
s6
A
V
Hz
kVA
kW
hp
 
V
V
V
V
A
μF
 
A
A
 
A
W
m
/h
3
kg
m
8.5 Motor Modules 85 A, 132 A and 200 A
Article No. 6SL5120-
1UE28-5AD0
1UE31-3AD0
 
85
113
170
0 ... 0.707 x DC link voltage
(0 ... 480 V at 680 V DC)
0 ... 550
62
45
60
495 ... 720
380 ... 432
106
1880
 
0.75
770
290
15
See Chapter "Maximum permissible cable lengths (Page 54)"
Motor Modules
1UE32-0AD0
 
 
132
200
176
230
264
400
1)
2)
97
147
75
110
100
150
 
820
24
165
250
2820
4080
 
250
20
 
 
0.75
0.8
1270
2070
290
340
17.2
20
221

Advertisement

Table of Contents
loading