IECEx – BVS 15.0107 X
The radio systems listed above, when properly equipped with the battery NNTN8570_, are certified for
use per the classification below:
Ex ib IIC T4 Gb (Approved for Zone 1, 2, Equipment group II, Gasgroup C, Temperature class T4)
Ex ib IIIC T90°C Db (Approved for Zone 21, 22, Equipment group III, Dustgroup C)
Ex ib I Mb (Approved for Zone M2, Equipment group I)
ATEX – BVS 12 ATEX E 117 X
The radio systems listed above, when properly equipped with the battery NNTN8570_, are certified for
use per the classification below:
II 2G Ex ib IIC T4 Gb (Approved for Category 2G/Zone 1, 2, Equipment group II, Gasgroup C,
Temperature class T4)
II 2D Ex ib IIIC T90°C Db (Approved for Category 2D/Zone 21, 22, Equipment group III, Dustgroup
C)
I M2 Ex ib I Mb (Approved Category/Zone M2, Equipment group I)
Ambient temperature range: -20°C ≤ Tamb ≤ 55°C
Ingress protection level: IP66/67
To view IECEx online certificate go to:
http://iecex.iec.ch/iecex/iecexweb.nsf/welcome
Operating safety instruction can be obtained from the Product Safety Leaflet MN002135A01 located in
the Motorola Solutions AGILE system or equivalent.

Operational Cautions for Intrinsic Safe Equipment

Radios must be shipped from the Motorola Solutions manufacturing facility with the hazardous
atmosphere capability and the intrinsic safety approval labeling (FM, UL, CSA, CENELEC, or ATEX/
IECEx). Radios will not be upgraded to this capability and labeled once they have been shipped to the