Yamaha S-03SL Owner's Manual page 81

Music synthesizer
Hide thumbs Also See for S-03SL:
Table of Contents

Advertisement

25. AEGSclSens
(AEG Scale Sensitivity)
This determines the AEG scaling parameters for each
Element. This parameter controls the degree of the
AEG according to the positions of notes on the
keyboard.
n The availability of the AEG Scale parameter depends on
the Break Point and Offset settings in the LvlScl display.
AEGSclSens
PAGE
PART
ELEM
KEY
25
E 1
OCTAVE
Settings: 0~15
26-1. AEGLvlVel
(AEG Level Velocity Sensitivity)
26-2. AEGAtkVel
(AEG Attack Velocity Sensitivity)
This determines the sensitivity of the Amplitude
Envelope Generator (AEG) to note velocity.
AEGLvlVel
00
PAGE
PART
ELEM
KEY
26
E 1
OCTAVE
Settings: 0~15
■ AEGLvlVel
This determines the sensitivity of the AEG Level to
note velocity. For higher values, the more strongly
you play the keys, the greater the change in volume
(AEG Level).
■ AEGAtkVel
This determines the velocity sensitivity of the AEG'
Attack Rate. For higher values, the Attack Rate
becomes faster the harder you play the keyboard.
00
AEGAtkVel
00
PAGE
PART
ELEM
KEY
26
E 1
OCTAVE
27. LvlSclFlag
(AEG Level Scale Flag)
You can set four Amplitude Scaling Break Points for
each Element. Amplitude Scaling controls the
amplitude according to the positions of the notes on
the keyboard. There are four Break Points used to
divide and assign different settings across the
keyboard. The Levels (Offsets) at each of Break Point
are set in the Level Offset display (PAGE 30).
n Details about Amplitude Scaling are given later in the
section "Amplitude Scaling Settings" below.
n The Levels of the Elements themselves are set in the
Level (PAGE 3) display (page 73).
LvlSclFlag
PAGE
PART
ELEM
KEY
27
E 1
OCTAVE
Settings: brk.p (applies the BP parameter settings in the
following PAGES), table (applies the settings which
are preset for each voice)
28-1. Lvl BP1 (Level Break Point 1)
28-2. Lvl BP2 (Level Break Point 2)
28-3. Lvl BP3 (Level Break Point 3)
28-4. Lvl BP4 (Level Break Point 4)
Set the Break Points for each Element. BP1 to BP4 will
be automatically be arranged in ascending order across
the keyboard.
Lvl BP1
C0
PAGE
PART
ELEM
KEY
28
E 1
OCTAVE
Lvl BP3
C6
PAGE
PART
ELEM
KEY
28
E 1
OCTAVE
Settings: Lvl BP1~Lvl BP4: C-2~G8
brk.p
Lvl BP2
G#0
PAGE
PART
ELEM
KEY
28
E 1
OCTAVE
Lvl BP4
C7
PAGE
PART
ELEM
KEY
28
E 1
OCTAVE
81
Element Amplitude

Advertisement

Table of Contents
loading

This manual is also suitable for:

S03

Table of Contents