Lincoln Electric OPTIMARC CV500 Service Manual page 14

Table of Contents

Advertisement

SVM7007
                                                                               
 
14. ARC CONTROL 
This knob controls the arc output characteristic. 
When it is turned clockwise, the arc is crisper. 
When it turned counter‐clockwise, the arc is softer. 
 
15. LOCAL OUTPUT CONTROL 
When the CONTROL SWITCH is set to "LOCAL", The 
output voltage ( CV mode ) or output current ( CC 
mode ) will be controlled by this knob. 
In TIG mode, it will control the maximum output 
current. 
In stick mode, it will control the output current 
range. 
 
16. NEGATIVE OUTPUT STUD 
 
17. POSITIVE OUTPUT STUD 
 
18. 6‐PIN AMPHENOL CONNECTOR 
Please see the FIGURE A.7 for the details of the 
connection. Recommend remote controller for 
GTAW mode is K870 ( Foot amptrol ), and 
recommend remote controller for SMAW is K857 
( Pot control ). 
 
19. 6‐PIN WIRE FEEDER CONNECTOR 
Please see the FIGURE A.6 for the details of the 
connection. 
 
20. STATUS INDICATOR 
The status light will be green for normal operation.  
The status light will flash in red with a serial of error 
digital codes as power source gets in some trouble.  
The status light will always have synchronization 
with the LED3 on switchboard inside machine. 
 
 
REAR PANEL (PLEASE SEE FIGURE B.2) 
 
21. INPUT CABLE HOLDING BRACKET 
This bracket securely holds the three phase power 
cables in place. 
 
22. INPUT BOX 
This insulation box is used to cover the input 
connections. 
    WARNING 
This insulation box must be secure before turning on 
the main power supply. 
 
23. GROUND LEAD CONNECTION 
Connect the ground lead to the paint‐free location 
on the case back by securing its lug‐end with the 
screw into the case. 
 
 
OPERATION
                                                                                               
24. AUX. POWER RECEPTACLE 
Export type machine: This is a 220V/200W auxiliary 
power output socket, for gas heater. 
 
Only plug the correct gas heater into this receptacle. 
DO NOT plug other electric devices into the 
receptacle, otherwise, damage may occur to the 
 machine. 
 
25. FUSE AND FUSE HOLDER 
Export type machine: 250V/2A fuse is used to 
protect the auxiliary 220V power outlet. 
 
26. FUSE AND FUSE HOLDER 
250V/8A fuse is used to protect the auxiliary power 
for the wire feeder. 
 
 
 
 
 
®
OPTIMARC
CV/CC500
    CAUTION 
FIGURE B.2 – REAR PANEL 
B‐4 
 
 