IM3098
12/2022
REV05
CITOCUT 60 & 100
OPERATOR'S MANUAL
ENGLISH
Lincoln Electric Bester Sp. z o.o.
ul. Jana III Sobieskiego 19A, 58-260 Bielawa, Poland

Advertisement

Table of Contents
loading

Summary of Contents for Lincoln Electric OERLIKON CITOCUT 60

  • Page 1 IM3098 12/2022 REV05 CITOCUT 60 & 100 OPERATOR’S MANUAL ENGLISH Lincoln Electric Bester Sp. z o.o. ul. Jana III Sobieskiego 19A, 58-260 Bielawa, Poland...
  • Page 2: Table Of Contents

    12/05 THANKS! For having choosen the QUALITY of the Lincoln Electric products.  Please Examine Package and Equipment for Damage. Claims for material damaged in shipment must be notified immediately to the dealer.  For future reference record in the table below your equipment identification information. Model Name, Code & Serial Number can be found on the machine rating plate.
  • Page 3: Technical Specifications

    Technical Specifications NAME INDEX CITOCUT 60 W000403595 CITOCUT 100 W000403597 INPUT Input Voltage Input Power at Rated Output EMC Class Frequency 4.3kW @ 100% Duty Cycle CC60 5.5kW @ 60% Duty Cycle 50/60Hz 7.1kW @ 40% Duty Cycle 400V  15% Three Phase 7.1kW @ 100% Duty Cycle CC100...
  • Page 4: Eco Design Information

    ECO design information The equipment has been designed in order to be compliant with the Directive 2009/125/EC and the Regulation 2019/1784/EU. Efficiency and idle power consumption: Efficiency when max power consumption Index Name Equivalent model / Idle power consumption W000403595 CITOCUT 60 87,6% / 21W No equivalent model...
  • Page 5 Typical gas usage for MIG/MAG equipment: DC electrode positive Wire Wire Feeding Gas flow Material type diameter Shielding Gas Current Voltage [m/min] [l/min] [mm] Carbon, low 0,9 ÷ 1,1 95 ÷ 200 18 ÷ 22 3,5 – 6,5 Ar 75%, CO alloy steel Aluminium 0,8 ÷...
  • Page 6: Electromagnetic Compatibility (Emc)

    If any electromagnetic disturbances are detected the operator must put in place corrective actions to eliminate these disturbances with, if necessary, assistance from Lincoln Electric. This equipment does not comply with IEC 61000-3-12. If it is connected to a public low-voltage system, it is responsibility of the installer or user of the equipment to ensure, by consultation with the distribution network operator if necessary, that the equipment may be connected.
  • Page 7: Safety

    Failure to follow the instructions in this manual could cause serious personal injury, loss of life, or damage to this equipment. Read and understand the following explanations of the warning symbols. Lincoln Electric is not responsible for damages caused by improper installation, improper care or abnormal operation.
  • Page 8 The plasma arc can cause injury and burns. Keep your body away from nozzle and plasma arc. Turn off power before disassembling torch. Do not grip material near cutting path. Wear complete body protection. Electric shock from torch or wiring can kill. Wear dry insulating gloves.
  • Page 9: Installation And Operator Instructions

    Installation and Operator Instructions Read this entire section before installation or operation of It is important to check these conditions because many the machine. engine driven generators produce high voltage spikes. Operation of this machine on engine driven generators not Location and Environment conforming to these conditions is not recommended and may damage the machine.
  • Page 10 (or in the machine torch connector). Panel lights up. If one or some LED remains OFF, contact the nearest technical service center or Lincoln Electric and To restore the machine: report the LED Status found on the machine Front Panel.
  • Page 11 ON again. If the error remains, a F.A.N. (Fan maintenance is required. Please contact the nearest Needed) circuitry technical service center or Lincoln Electric and report the inside: LED Status found on the machine Front Panel. automatically turned OFF.
  • Page 12 Cutting Process The air plasma cutting process uses air or nitrogen as primary cutting gas and as torch cooling gas. The pilot arc is struck as follow: the torch button energize an electrovalve (solenoid valve). This valve lets the gas flow during the cutting and the post-flow stages.
  • Page 13 Cutting Speed The cutting speed is a function of:  Thickness and of material to be cut.  Value of set current. The current setting affects the quality of the cut edge.  Geometrical shape of the cut (whether straight or curved).
  • Page 14 We respond to our customers based on the best information in our possession at that time. Lincoln Electric The frequency of the maintenance operations may vary in is not in a position to warrant or guarantee such advice, accordance with the working environment.
  • Page 15: Weee

    Authorized Service Shops Location 09/16  The purchaser must contact Lincoln Electric or Authorized Service Facility about any defect claimed under warranty period.  Contact your local Sales Representative for assistance in locating the nearest Authorized Service Facility.