Technical specifications
8.1 FMS500
Table 8-2
Process connections
Version
EN 1092-1
ANSI B16.5
AWWA C-207
AS4087
JIS B 2220
Table 8-3
Rated operating conditions
Version
Ambient temperature
 
Sensor
 
With compact transmitter FMT020
Operating pressure [abs. bar]
Enclosure rating
 
Standard
 
Optional
46
1
FMS500
PN 6
DN 1400 to 1200 (56" to 48")
Raised face flanges
PN 10 (145 psi):
DN 200 to 300 (8" to 12")
Flat face flanges
PN 10 (145 psi):
DN 350 to 1200 (14" to 48")
Raised face flanges
PN 16 (232 psi):
DN 50 to 300 (2" to 12")
Flat face flanges
PN 16 (232 psi):
DN 350 to 1200 (14" to 48")
Raised face flanges
PN 40 (580 psi):
DN 15 to 40 (½" to 1½")
Flat face flanges
Class 150 lb: ½" to 24"
Class D:
28" to 78", Flat face flanges
PN 16 (230 psi):
DN 50 to 1200 (2" to 48")
K10 (1" to 24")
FMS500
 
-20 to +70 °C (-4 to +158 °F)
-20 to +65 °C (-4 to +149 °F)
DN 15 to 40 (½" to 1½")
0.01 to 40 bar (0.15 to 580 psi)
DN 50 to 300 (2" to 12")
2
0.03 to 20 bar (0.44 to 290 psi)
DN 350 to 1200 (14" to 48")
0.01 to 16 bar (0.15 to 232 psi)
 
IP66/67, NEMA 4X/6
IP68 and NEMA 6P (2m, 10 days) for sensor in remote design
IP68 and NEMA 6P (10m, continuously) for sensor in remote
design