Step 4
LP Conversion
Step 3
Electrode
Use 7mm nutdriver/socket to change orifice's
Quantity of Orifice's
CCB150 = 17
CHB100 = 11
CHB130 = 15
NG Orifice size 1.35mm
LP Orifice size 0.85mm
Remove 2 Screws
right side & 2 on
left
Remove
Burner Assy