Air Pressure Transducer – All Models
Air pressure transducer sends the PCB a signal to drive the fan:
With short chimney fan speed will be lower
With long chimney fan speed will be higher
This is to compensate for chimney conditions & results in constant efficiency of the boiler @ max and min
power
P2 = Venturi
P1 = Sealed chamber