FAULTS AND SYSTEM EVENTS

The faults and system events are displayed in the home and
dormant screen banners. See Table 10. Faults and system events
include:
Startup
Software Update Events
Power Cycle Events
Parameter Out-of-Range Events
FAULTS
ID TEMP SENSOR HIGH
ID TEMP SENSOR LOW
REMOTE SENSOR HIGH
REMOTE SENSOR LOW
ID TEMP RANGE HIGH
ID TEMP RANGE LOW
HUM SENSOR FAILURE
HUMIDITY RANGE HIGH
HUMIDITY RANGE LOW
OUTDOOR TEMP FAILURE
NO WI-FI SERVER
NO WI-FI ROUTER
WI-FI HARDWARE FAULT
LOCKOUT 5 WRONG PINS
ECONOMIZER FAULT
HIGH CO2
SYSTEM EVENTS
FILTER REMINDER
The faults and system events display in the banner while fault
condition exists. You can see a history of the faults and system
events in WIFIStat mobile app under Alerts. The history is
comprised of the 5 most recent logged items, with the most recent
event being listed at the top.
Table 10 — Fault and System Events
Fault becomes active when main thermistor (P102 or RT1) reads > 100°F.
Fault is cleared when temperature <= 99°F.
When this fault occurs, the thermostat uses the temperature reading from
the temperature/humidity sensor as the space temperature.
Fault becomes active when main thermistor (P102 or RT1) reads < 39°F.
Fault is cleared when temperature >= 40°F.
When this fault occurs, the thermostat uses the temperature reading from
the temperature/humidity sensor as the space temperature.
Remote temperature > 122°F; only flagged if remote sensor set to use as
indoor temperature (REMOTE SENSOR setting set to INDOOR or
AVERAGE)
Remote temperature = 0°F; only flagged if remote sensor set to use as
indoor temperature (REMOTE SENSOR setting set to INDOOR or
AVERAGE)
If the mode is cooling (Cool or Auto operating in Cool), the space
temperature is greater than the cool setpoint plus the Maximum Setpoint
Error and this condition exists for the number of minutes specified by the
INDOOR TEMP FAULT INHIBIT time.
If the mode is heating (HEAT, EHEAT or AUTO operating in HEAT), the
space temperature is less than the heat setpoint minus the Maximum
Setpoint Error and this condition exists for the number of minutes specified
by the INDOOR TEMP FAULT INHIBIT time.
Humidity sensor timed out
humidity reading is > 99%
humidity reading is 0%.
Humidity reading is > 90%
Humidity reading is < 10%
OD temp > 127°F or < -60°F
Not connected to Ayla server
Router signal strength is (not connected)
Communications error occurred with Wi-Fi module (resets after valid
message received)
An incorrect PIN was entered consecutive times.
Remote sensor is set to ECFL and there is a short between terminals T
and C.
CO
is above the programmed threshold (default 1100 ppm).
2
Filter change reminder is active (run hours have expired or remote input
shorted).
23
Server Connectivity Events
Non-Volatile Memory Faults
Temperature Faults