Daikin UK.PPC150SL/R32 Installation Manual
Daikin UK.PPC150SL/R32 Installation Manual

Daikin UK.PPC150SL/R32 Installation Manual

Domestic hot water pre plumbed tank for daikin altherma r32 monobloc systems

Advertisement

Domestic Hot Water Pre Plumbed Tank for Daikin
UK.PPC150SL/R32
UK.PPC150/R32
UK.PPC180SL/R32
UK.PPC180/R32
UK.PPC210/R32
UK.PPC250/R32
UK.PPC300/R32
Altherma R32 Monobloc Systems
Domestic hot water tank for Daikin Altherma R32 Monobloc systems
Installation Manual
Installation Manual
English

Advertisement

Table of Contents
loading

Summary of Contents for Daikin UK.PPC150SL/R32

  • Page 1 Installation Manual Domestic Hot Water Pre Plumbed Tank for Daikin Altherma R32 Monobloc Systems UK.PPC150SL/R32 UK.PPC150/R32 UK.PPC180SL/R32 UK.PPC180/R32 UK.PPC210/R32 UK.PPC250/R32 Installation Manual English Domestic hot water tank for Daikin Altherma R32 Monobloc systems UK.PPC300/R32...
  • Page 2 CAUTION Indicates a situation that could result minor or moderate injury. Wear adequate personal protective equipment (protective gloves, safety glasses,…) when installing, maintaining or servicing the system UK.PPC150-300(SL)/R32 November 2022—Version 2.1 Domestic hot water tank for Daikin Altherma Monobloc (R32)
  • Page 3: Preparing The Installation Site

    Particular care is needed if the cylinder is to be installed in an exposed location such as an outhouse or garage. UK.PPC150-300(SL)/R32 November 2022—Version 2.1 Domestic hot water tank for Daikin Altherma Monobloc (R32)
  • Page 4: Safety Device Requirements

    All components procured on-site and all electrical construction • MUST comply with the applicable legislation Overview: Installation This chapter describes what you have to do and know on-site to install the systems. UK.PPC150-300(SL)/R32 November 2022—Version 2.1 Domestic hot water tank for Daikin Altherma Monobloc (R32)
  • Page 5 The discharge pipe away from the tundish must terminate in a • safe, visible position without forming any risk to persons in the vicinity. UK.PPC150-300(SL)/R32 November 2022—Version 2.1 Domestic hot water tank for Daikin Altherma Monobloc (R32)
  • Page 6: About Electrical Compliance

    ALWAYS use multicore cable for power supply cables. Immersion heater comes complete with integral control thermostat and a high limit cut-out. If a replacement is required please order them from Daikin UK, installation of a non-approved immersion may affect your warranty.
  • Page 7: Parts List

    4.5.5 Parts List 4.5.6 Plan View and Dimensions Allow 300mm space in front for servicing immersion heater.
  • Page 8 From the factory, the pre plumbed cylinder will be supplied with the vessel as a hydraulic separator. In order to change the vessel to function only as a volumiser, use the following configuration. Daikin Pre-Plumbed Cylinder with Hydraulic Separation Daikin Pre-Plumbed Cylinder with Inline Volumizer...
  • Page 9: Checklist During Commissioning

    The pressure relief valve purges water when opened. The minimum water volume is guaranteed in all conditions. Be sure field wiring has been carried out according to the instructions described. UK.PPC150-300(SL)/R32 November 2022—Version 2.1 Domestic hot water tank for Daikin Altherma Monobloc (R32)
  • Page 10: Annual Maintenance

    NOTICE be necessary. When using means for descaling or chemical disinfection, it must be ensured that the water quality remains compliant with EU directive 98/83 EC. UK.PPC150-300(SL)/R32 November 2022—Version 2.1 Domestic hot water tank for Daikin Altherma Monobloc (R32)
  • Page 11: Overview: Troubleshooting

    Inlet control group (field supply). The cold water inlet pressure reducing Check and refit as required. valve is not fitted properly. UK.PPC150-300(SL)/R32 November 2022—Version 2.1 Domestic hot water tank for Daikin Altherma Monobloc (R32)
  • Page 12 Do NOT use Dixell control panel for DHW setpoint. This control • panel should only be used to set the water temperature used to run the on board pump for space heating. UK.PPC150-300(SL)/R32 November 2022—Version 2.1 Domestic hot water tank for Daikin Altherma Monobloc (R32)
  • Page 13 Technical data 12.1 Components: Domestic hot water tank 12.2 Exploded Diagram UK.PPC150-300(SL)/R32 November 2022—Version 2.1 Domestic hot water tank for Daikin Altherma Monobloc (R32)
  • Page 14: Technical Specifications

    Height 1869 1970 Diameter Empty weight Material inside cylinder Stainless steel 2304 Piping connections Water inlet H/E (diameter) Water outlet H/E Cold water in Hot water out UK.PPC150-300(SL)/R32 November 2022—Version 2.1 Domestic hot water tank for Daikin Altherma Monobloc (R32)
  • Page 15 Optional equipment Equipment made or approved by Daikin that can be combined with the product according to the instructions in the accompanying documentation.
  • Page 16 Appendix: Wiring Connections Factory Fitted Wiring Wiring when using Madoka (BRC1HHD) Controller...
  • Page 17 Appendix: Wiring Connections Cont’d Third party controller must be volt free and TPI disabled. Cable must be sized for 230V Wiring when using Third Party Thermostat (1 Zone) Third party controller must be volt free and TPI disabled. Cable must be sized for 230V Wiring when using Third Party Thermostat (2 Zones)
  • Page 18: Customer Details

    Building Regulations. 3. Failure to install and commission this appliance to the manufacturer’s instructions may invalidate the war- ranty. The above does not affect your statutory rights. UK.PPC150-300(SL)/R32 November 2022—Version 2.1 Domestic hot water tank for Daikin Altherma Monobloc (R32)
  • Page 19: Unvented Systems

    COMPETENT PERSON’S SIGNATURE CUSTOMER SIGNATURE (To confirm demonstrations of equipment and receipt of appliance instructions) PLEASE FOLLOW THE INSTALLATION AND COMMISSIONING INSTRUCTIONS IN THE MANUAL SUPPLIED WIITH THE EQUIPMENT UK.PPC150-300(SL)/R32 November 2022—Version 2.1 Domestic hot water tank for Daikin Altherma Monobloc (R32)
  • Page 20 TEL No. TEL No. COMMENTS COMMENTS SIGNATURE SIGNATURE When all the above services have been completed, please contact your Service Engineer for an additional service internal record sheet UK.PPC150-300(SL)/R32 November 2022—Version 2.1 Domestic hot water tank for Daikin Altherma Monobloc (R32)
  • Page 21 UK.PPC150-300(SL)/R32 November 2022—Version 2.1 Domestic hot water tank for Daikin Altherma Monobloc (R32)
  • Page 22 Daikin UK 1, The Heights, Brooklands, Weybridge, Surrey, KT13 0NY...

Table of Contents