Advertisement

Quick Links

802CN/802-II
Vibration Meter
Users Manual
(English)
August 2015 Rev. 1, 6/23
©2022-2023 Fluke Corporation. All rights reserved.
Specifications are subject to change without notice.
All product names are trademarks of their respective companies.

Advertisement

Table of Contents
loading

Summary of Contents for Fluke 802CN

  • Page 1 802CN/802-II Vibration Meter Users Manual (English) August 2015 Rev. 1, 6/23 ©2022-2023 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their respective companies.
  • Page 2 LIMITED WARRANTY AND LIMITATION OF LIABILITY Each Fluke product is warranted to be free from defects in material and workmanship under normal use and service. The 802CN warranty period is 1 year and begins on the date of shipment. The 802-II warranty period is 2 years and begins on the date of shipment. Parts, product repairs, and services are warranted for 90 days.
  • Page 3: Table Of Contents

    Table of Contents Title Page Introduction..........................................Safety Information ........................................Contact Fluke ........................................... Accessories ..........................................Specifications........................................... Before You Start ........................................Unpack and Inspect ...................................... Storage ..........................................Battery ..........................................Display............................................Controls and Connections ....................................Power On/Off ..........................................Auto Power Off......................................... How to Operate........................................
  • Page 4 802CN/802-II Users Manual Backlight........................................Flashlight........................................Accessory Connectors ....................................External Sensor ..................................... Audio ......................................... 11 ISO 10816 Standards....................................12 ISO 10816-1 ......................................12 Important Terms ....................................13 General Maintenance ......................................13 Care..........................................13 How to Clean ......................................13 Battery Replacement................................... 14...
  • Page 5: Introduction

    Introduction Contact Fluke The 802CN/802-II Vibration Meter (the Product) is a Fluke Corporation operates worldwide. For local contact screening tool for overall vibration measurements on information, go to our website: www.fluke.com. machines. The Product includes these features: To register your product, or to view, print, or download the •...
  • Page 6: Accessories

    802CN/802-II Users Manual Accessories Velocity Range .......... 0.1 mm/s to 199.9 mm/s rms Table 1 is a list of the accessories available for the Product. Resolution........0.1 mm/s Accuracy ........±(5 % +2 digits) (10 Hz to 1 kHz) Table 1. Accessories...
  • Page 7 Vibration Meter Specifications Amplitude Units Vibration Limit ......500.0 m/s² peak Electromagnetic Compatibility Acceleration........g, m/s International........IEC 61326-1: Portable Velocity........... mm/s Electromagnetic Environment Displacement ....... mm CISPR 11 ........Group 1, Class A Battery Type........2 AAA, IEC LR03 Group 1: Equipment has intentionally generated and/or uses External Piezoelectric Accelerometer conductively-coupled radio frequency energy that is...
  • Page 8: Before You Start

    802CN/802-II Users Manual Before You Start Display Table 2 shows the typical elements on the Product display. This section helps you to know the Product parts, controls, and connections. Table 2. Typical Elements on the Product Display Unpack and Inspect Carefully unpack and inspect the: •...
  • Page 9: Controls And Connections

    Vibration Meter Controls and Connections Controls and Connections Table 3 shows the location of the controls and connections for the Product. Table 3. Product Controls and Connections Item Control Power on/off Measure Save/mode switch/unit switch Bottom cap View records Backlight on/off and flashlight on/off Flashlight Piezoelectric Accelerometer Audio port...
  • Page 10: Power On/Off

    802CN/802-II Users Manual Power On/Off  • Push to view existing reading or clear all stored data. Push and hold O for over one second to turn on/off the Product. See Table 3 for the control location. Measurement Modes When you turn on the Product, the default Measurement The units of measure are adjustable for different standards.
  • Page 11: Save Measurement Reading

    Vibration Meter How to Operate Figure 1. Correct and Incorrect Measurement Angles After startup, the Product is in standby mode. The main screen shows “----“ and the last set measurement unit.  1. Push and hold to enter measurement mode and view measurement reading.
  • Page 12: View Memory

    802CN/802-II Users Manual Clear All Data  Push to save the reading. SAVE no longer flashes on the screen. Instead, the memory location shows on the  In View Memory mode, push and hold for over upper-left of the screen. Quick measurements are saved as 5 seconds to clear all stored data.
  • Page 13: Accessory Connectors

    Vibration Meter How to Operate Figure 2. Flashlight Note The Product supports but does not provide an external accelerometer. Go to http:// www.fluke.com.cn/ to purchase an external accelerometer. Figure 3. External Accelerometer Accessory Connectors The Product has two accessory connectors: •...
  • Page 14 802CN/802-II Users Manual To set the sensitivity for the external sensor: 1. Turn on the Product while pushing  at the same time. The screen shows the model number and software version number. Note You must set the sensitivity in mV/m/s² units.
  • Page 15: Audio

    Vibration Meter How to Operate Audio Figure 4. Audio Connection The Product has an audio connector for headphones. Headphones are useful to detect unusual machine sounds. To listen to a machine: 1. Open the bottom cap of the Product and connect the audio connector.
  • Page 16: Iso 10816 Standards

    802CN/802-II Users Manual ISO 10816 Standards Table 4. Vibration Severity - ISO 10816-1 As an alternative to the Overall Vibration Severity Scale Machine Class I Class II Class III Class IV included in the Product, you can use the ISO Standard...
  • Page 17: Important Terms

    Vibration Meter General Maintenance Important Terms W Caution Class I: Individual parts of engines and machines integrally To prevent damage to the Product or any connected to the machine in normal operation. Production performance loss, do not put the Product in electrical motors at a maximum of 15 kW are examples of temperature extremes.
  • Page 18: Battery Replacement

    802CN/802-II Users Manual Battery Replacement Figure 5. Battery Replacement The Product operates on two AAA batteries. To replace the batteries: 1. Turn the Product over and loosen the battery cover screw. 2. Remove the battery cover from the Product, see Figure 3.
  • Page 19: How To Troubleshoot

    Vibration Meter General Maintenance How to Troubleshoot Table 5 is a list of problems, causes, and corrective actions for the Product.If the problem continues, contact the Fluke Service Center for technical support. See Contact Fluke Table 5. Troubleshooting Symptom Cause Corrective Action 1.
  • Page 20 802CN/802-II Users Manual...

This manual is also suitable for:

802-ii

Table of Contents