▶ Open the top flap on the burner controller and unplug the plug
(Fig. 6).
Fig. 6
Unplug the plug from the burner control unit
▶ Loosen the cable on the side and at the top of the supporting plate,
and place on top of the boiler (Fig. 7).
▶ Remove the 6 screws on the supporting plate for the air hose and take
off the supporting plate (Fig. 7, [1+2]).
▶ Unplug both plugs on the differential pressure sensor (Fig. 7, [3]).
▶ Unplug the plug on the solenoid valve (Fig. 7, [4]).
4
Fig. 7
Loosen the cable and remove the supporting plate
[1]
6x screws
[2]
Supporting plate for air hose
[3]
Plug on differential pressure sensor
[4]
Plug for solenoid valve
Condens 7000 FP – 6721846699 (2022/12)
▶ Unplug the plug on the fan (Fig. 8).
Fig. 8
Unplug the plug from the fan
▶ Unplug the plug on the ignition transformer (Fig. 9).
▶ Remove the 4 nuts on the mixture manifold / front section (Fig. 9).
1
2
1
Fig. 9
Unplug the plug on the ignition transformer and remove the nuts
on the mixture manifold / front section
[1]
Plug on the ignition transformer
[2]
Nuts on the mixture manifold
3
▶ Pull the mixture manifold with burner rod and fan back to the end
position (O-ring on the guide pin)
▶ Remove the mixture manifold with burner rod as described in chapter
11.7 for the Figs. 50 and 51.
▶ Remove the 4 screws on the holding plate of the burner base
(Fig. 10, [2]).
Transporting the boiler
0010041660-001
0010041665-001