System Message
GIA #1 INOP: SERL
– Internal GIA Serial
Communication Fault.
GIA #1 INOP: VOLT –
Check GIA Voltage.
GIA #1 OVER TEMP –
Check GIA Temperature.
GIA #2 FAN FAIL –
Fan fault, check GIA
temperature.
GIA #2 INOP - CRNT –
Check GIA Current.
GIA #2 INOP: SERL
– Internal GIA Serial
Communication Fault.
GIA #2 INOP: VOLT –
Check GIA Voltage.
GIA #2 OVER TEMP –
Check GIA Temperature.
GLIDE/ASSIST RING
ASSIST – Unavailable
above [#}.
GLIDESLOPE #1 INOP:
INTRL – Glideslope Internal
Fault
GLIDESLOPE #2 INOP:
INTRL – Glideslope Internal
Fault
GMA 1 INOP: COMM –
GMA Communication Fault.
GMA 1 INOP: INTRL –
GMA Internal Fault.
GMA 1 INOP: SOFTWARE
– GMA CRC Fault.
GMA 1 INOP: VOLTAGE
– Voltage outside standard
range.
190-02954-01 Rev. A
Cockpit Reference Guide for the Cirrus SR2x with Perspective Touch+ by Garmin
Comments
GIA 1 serial communication fault. Check GIA serial communication.
GIA 1 low voltage. Check voltage.
GIA 1 is reporting an over-temperature condition.
GIA #2 fan failure. Monitor GIA #2 temperature.
GIA 2 current is low. The current should be checked.
GIA 2 serial communication fault. Check GIA serial communication.
GIA 2 low voltage. Check voltage.
GIA 2 is reporting an over-temperature condition.
Glide assist / glide ring unavailable above specified altitude.
The Glideslope sub-system of the GIA is inoperative due to an internal
fault.
The Glideslope sub-system of the GIA is inoperative due to an internal
fault.
There is a problem with the GMA 1 config module connection. Check the
connection.
GMA 1 has an internal fault. The system should be serviced.
The GMA is inoperative due to a CRC fault.
The GMA is inoperative due to a voltage fault.