RUA 5308X, RUA 6508X, RUA 8508X
Connection variant B (fig. o)
o
Vehicle Anderson plug must
be controlled by ignition relay.
• Anderson plug controlled from the vehicle relay to the ignition switch.
• Power supply only when the engine is running.
• D+ is bridged to the starting battery connection (fig. l 23, page 23).
• No charging of the house battery by the vehicle.
Connection variant C (fig. p)
p
Vehicle Anderson plug must
be controlled by ignition relay.
• D+ is switched on and off via a fridge motion switch (not included), depending on whether the vehicle is in
motion or not.
• No charging of the house battery by the vehicle.
EN
Refrigerator DC connections
D+
25
House Battery
Anderson Plug
Anderson cables must be the
recommended size.
Refrigerator DC connections
D+
Power Module
25
House Battery
Anderson Plug
Anderson cables must be the
recommended size.
Connecting the refrigerator
Power Module
Heater
+
-
+
26
Heater
+
-
+
-
26
23
-
23
Fridge
Switch
27