Download Print this page

Dometic RUA5308X Installation Manual page 25

Absorption refrigerator
Hide thumbs Also See for RUA5308X:

Advertisement

RUA 5308X, RUA 6508X, RUA 8508X
Connecting to DC power supply
The electrical power supply must be connected by a qualified electrician who has
demonstrated skill and knowledge related to the construction and operation of
electrical equipment and installations, and who is familiar with the applicable
regulations of the country in which the equipment is to be installed and/or used,
and has received safety training to identify and avoid the hazards involved.
!
WARNING! Electrocution hazard
Observe the recommended cable cross-sections, cable lengths and fuses.
!
CAUTION! Fire hazard
Place the fuse near the starting battery to protect the cable from short circuits and pos-
sible burning.
A
NOTICE! Damage hazard
• Do not connect the respective negative and positive cables of the DC connections
for heating and control to avoid electrical interference or damage to electrical
components.
• To avoid voltage drops and power losses, keep the connection cable uninterrupted
and as short as possible. Do not install additional switches, plugs or socket strips.
m
No. in fig. m
Description
1
Fuse (30 A)
2
Ignition on/off relay