PREPARING FOR FIELD LEVEL TESTING: Connecting an i530 Unit to the R-2660
7. Attach the power leads on the battery eliminator to the DC power supply.
CAUTION: Be very careful to observe polarity when connecting power to the
battery eliminator. Also, be sure to protect the test setup from any potential
overvoltage condition.
8. Turn on the power supply, and adjust it for an output between 5.0 Vdc and 12.0 Vdc.
NOTE: With the power supply voltage set between 5.0 Vdc and 12.0 Vdc, the battery
eliminator will provide a regulated 4.0 Vdc to the unit.
9. Power up the unit.
Refer to the R-2660 Digital Communications System Analyzer Operator's Manual for more
information on how to use this equipment.
7.3.1

Operating the R-2660

Most of the technician tests performed with the R-2660 Communications System Analyzer require
that the analyzer use the Initial Registration test mode.
To enter Initial Registration mode:
1. Turn on the R-2660.
2. Press DISP to place the cursor in the Display zone portion of the screen.
3. Use the arrow keys to move the cursor to the Mode field.
4. Press More until iDEN MOBILE appears in the Mode field.
5. Press the iDEN MOBILE softkey. The RF zone displays DUPLEX in the RF Control field.
6. Use the arrow keys to move the cursor to the Meter field in the display zone.
7. Press More until INITIAL REG appears in the Meter field.
8. Press the INITIAL REG softkey. The display zone displays DISPATCH in the Registration
Type field.
9. Press RF to move to the RF zone.
7-4
68P80400P65-O