3) Remove the connecting
rod and measure the plastigauge.
PLASTIGAUGE
Standard
Service limit
0.040 - 0.066 mm
0.12 mm
(0.0016 - 0.0026 in)
(0.005 in)
4) If the clearance
exceeds the
service
limit,
replace the
connecting
rod and recheck the
clearance.
• CAMSHAFT CAM HEIGHT
------
Standard
Service limit
IN
31.85
-
32.25 mm
31.10
mm
(1.254-1.270
in)
(1.224 in)
EP5000
EX
31.57 - 31.97 mm
30.80 mm
(1.243 -1.259
in)
(1.213 in)
IN
32.40 - 32.80 mm
32.25
mm
(1.276-1.291
in)
(1.270 in)
EP6500S
EX
31.89 - 32.29 mm
31.75
mm
(1.256-1.271
in)
(1.250
in)
• CAMSHAFT
0.0.
Standard
Service limit
15.984 mm
15.92 mm
(0.6293 in)
(0.627 in)
CAMSHAFT
HOLDER
1.0.
Standard
Service
limit
16.0 mm
16.05 mm
(0.63 in)
(0.632 in)
PLASTIGAUGE
SCALE