Honda EM6000GN Manual page 14

Table of Contents

Advertisement

HONDA
EM6000GN
15) Start the engine
again.
OIL ALERT UNIT
16)
Attach one tester lead to the white/yellow
terminal and
the
other
tester lead to the black terminal
of the valve
control unit 4P connector.
17)
Disconnect
the yellow connector from the oil alert unit
and attach it to the engine to
ground.
Be sure that the
engine
stops.
18) Measure
the voltage
between
the white/yellow
and
black terminals
of the 4P connector within 0.5 seconds
after the engine
stop.
It must be 0 V.
19) If the engine
does not stop, check the oil alert
unit.
Replace the oil alert unit if
necessary.
20) If the measured voltage is not 0 V within
0.5 seconds
after the engine stop, replace the valve control unit.
21) The valve
control
unit is normal if the above procedures
checked out all
right.
• HOUR METER
1)
Check for continuity
between the terminals
of the hour
meter 2P
connector.
There should be
continuity.
2)
Connect the 12 V battery voltage between the white/yel-
low and yellow/green
terminals
of the hour meter 2P
connector.
The hour meter must start within 8
seconds.
3)
The hour meter is
normal
if the step 1 and 2 checked
out all right.
YELLOW
WIRE
WHITEI
YELLOW
BLACK
12 V
6-3