Data - Rinnai RHFE-1004FA Owners & Installation Manual

Energysaver gas direct vent wall furnace
Hide thumbs Also See for RHFE-1004FA:
Table of Contents

Advertisement

TECHNICAL
DATA
WEIGHT
GAS RATE (BTU/h)
INPUT
OUTPUT
90 Lbs.
DIMENSIONS
Width: 36 5/8"
Height: 26 3/8"
Depth:
12 3/8"
NG
LP
NG
LP
LOW
10,500 10,500
LOW
8,400
8,400
HIGH
38,400
36,500
HIGH
30,720 29,200
Burner Orifices:
HI
LOW
NG
LPG
PARTS No.
QTY'
PARTS No.
QTY'
1004F-2031-2-1.80
2
1004F-2031-1-0.95
2
1004F-2036-2-1.95
1
1004F-2036-1-1.20
1
GAS CONVERSION
SPECIFICATIONS
MODEL
RHFE-1004FA-N
RHFE-1004FA-P
,
DIAMETER OF
iGAS
ORIFICE(mm)
TYPE
HI
LOW
NG
1.8O
1.95
LPG
0.95
1.20
DAMPER
A-DJUSTMENT
FRONT
RIGHT
LEFT
7/10
10/10
10/10
10/10
10/10
10/10
MANIFOLD DIFFERENTAL
PRESSURE (W.C.)
HI
LO
3.7"W.C.
2.0"W.C.
10.1"W.C.
4.3"W.C.
GAS SUPPLYPRESSURE
NATURAL
MINIMUM
5.0"W.C.
MAXIMUM
10.5"W.C.
PROPANE
11.0"W.C.
13.0"W.C.
• The minimum inlet gas supply pressures is for the purpose of input adjustment.
• Heaters may be converted from one gas to another using Rinnai conversion kits.
-56-