Rinnai RHFE-1004FA Owners & Installation Manual page 4

Energysaver gas direct vent wall furnace
Hide thumbs Also See for RHFE-1004FA:
Table of Contents

Advertisement

Overcurrent
Prevention
Device:
Power Outaqe
Safety Device:
This is a 5 amp. glass fuse found on P.C. board.
Design to
shut unit down in case of overcurrent.
If fuse blows all
indicator
lamps will be "OFF".
This safety device cuts off gas passage
and stops
operation.
Local and state codes must be adhered to prior to installation.
Rinnai is continually updating and improving products therefore specifications are subject to change
without prior notice.
NAT,
LPG
Minimum supply gas pressure
5.0" (127mmH20)
11.0" (279mmH20)
Maximum supply gas pressure
10.5" (267mmH20)
13.0" (330mmH20)
Manifold test pressure
Factory set
Factory set
•_See conversion for setting gas pressures.
•There's 1/8" NPT pipe tap provided for gas pressure test. That is located on the gas control assembly A.
The minimum inlet gas supply pressure is for the purpose of input adjustment.
f
GENERAL
INFORMATION
THIS SERIES
IS DESIGN
CERTIFIED
BY THE AMERICAN
GAS
ASSOCIATION
LABORATORIES
(AGA) AND
INTERNATIONAL
APPROVAL
SERVICES
(IAS).
ALTERATION
OF THE ORIGINAL
DESIGN
INSTALLED
OTHER
THAN AS SHOWN
IN THESE
INSTRUCTIONS
OR USED WITH
A TYPE
OF GAS NOT SHOWN
ON THE RATING
PLATE,
IS
THE
RESPONSIBILITY
OF THE
PERSON
AND
COMPANY
MARKING
THE CHANGE.
Thank you for purchasing
a Rinnai gas forced flue heater.
Before
using this product,
please
read this manual
carefully
to insure proper use of the product.
Please
read the attached
warranty
thoroughly
and keep it in a safe place.