Gfci And Wiring Specification - Cal Spas SWIM Owner's Manual

Table of Contents

Advertisement

8
240 Volt Electrical Specifications
240 Volt Electrical Specifications
Wiring Specifications and GFCI Requirement
Wiring Specifications and GFCI Requirement
Spa Model
F-1325 / F-1325X
F-1655 / F-1655X
F-1437 / F-1437X
F-1868DZ
F-1868DZ
*Optional 5.5 KW auxiliary heater will require one additional 40 amps GFCI breaker with three #6
AWG copper wires
8
Control System
GFCI Breaker
BP501X
One 50 Amp GFCI
Breaker
BP20X
One 60 Amp GFCI
Breaker
BP501X
One 50 Amp GFCI
Breaker
Service # 1 Swim Side
BP20X
One 60 Amp GFCI
Breaker
BP501G1
Service # 2 Spa Side
110V 15 Amp
Plug & Play
Wires Required
Wiring Diagram
Four #6 AWG Cop-
See Page 10
per Wires
for reference only
Four #6 AWG Cop-
See Page 10
per Wires
for reference only
Four #6 AWG Cop-
See Page 10
per Wires
for reference only
Four #6 AWG Cop-
See Page 10
per Wires
for reference only
Cord with15 Amp
See Page 10
GFCI Provided
for reference only