Technical Specifications
Air Control Solenoid Valve for Fluid Defender
Minimum Operating Pressure
Maximum Operating Pressure
Maximum Air Flow
Operating Power
Voltage
Current
Termination Style
Maximum Line Length (16 gauge) to Fluid
Defender
Maximum Line Length (18 gauge) to Fluid
Defender
Maximum Line Length (20 gauge) to Fluid
Defender
Maximum Line Length (22 gauge) to Fluid
Defender
Maximum Line Length (24 gauge) to Fluid
Defender
Port Size
Air Inlet
Air Outlet to Controlled Equipment
Exhaust
Temperature Range
Storage Temperature Range
Ingress Protection
Valve Schematic
California Proposition 65
CALIFORNIA RESIDENTS
WARNING: Cancer and reproductive harm – www.P65warnings.ca.gov.
3A7280A
US
36 psi
145 psi
93 scfm
3.3 W
24 VDC
0.14 A
Wire leads
1000 ft
600 ft
425 ft.
270 ft.
170 ft.
3/8 npt
Port 1
Port 2
Port 3
14°F to 122°F
-40°F to 185°F
IP65
Technical Specifications
Metric
250 kPa, 2.5 bar
1.0 MPa, 10 bar
3
2.6 m
/min.
304.8 m
182.9 m
129.5 m
82.3 m
51.8 m
-10°C to 50°C
-40°C to 85°C
13